The GE OEC 9600 C-arm is a mobile X-ray system that combines enhanced fluoroscopic imaging with the ability to take film radiographs. The OEC 9600 can be used in a variety of diagnostic and surgical applications.
The C-arm can orbit in its cradle through an arc of 115 degrees. The back of the C-Arm is marked with an angular scale to aid in positioning. The 9600 can also pivot on its cradle axis up to 180 degrees. This provides greater versatility in positioning the X-ray tube and image intensifier by allowing them to reverse or flip-flop their relative positions. The L-Arm of the C-arm can be rotated up to 180 degrees allowing up to 360-degree rotation. The L-arm is rotated with an internal motor using the motorized rotation buttons on the top of the C-arm control panel. For even more positioning the C-arm also has a vertical lift. It can be raised up to 18-inches (46 cm). The vertical lift is also controlled by a motor and can be operated with the motorized column life buttons on the top of the c-arm control panel. The GE 9600 can also be extended up to 8-inches (20cm). The entire C-arm and L-arm assembly can swing, or wig-wag from side to side up to 11 degrees both directions.
Specialty Packages Available GSP ESP Vascular Vascular: 4/8/15 fps Neurovascular: 30 fps Cardiac: 30 fps Super C Generator High frequency 4.0 kW full-wave Up to 120 kVp Up to 75 mA for radiographic film exposures Continuous fluoro boost mode up to 12 mA (optional) Pulsed fluoro mode Pulsed fluorography mode up to 40 mA Full power from outlet: 50 Hz or 60 Hz 100V-15A to 240V-8A Patented energy buffer design X-Ray Tube Rotating anode X-ray tube Focal spots: 0.3 mm and 0.6 mm Anode heat capacity: 300,000 HU Anode cooling rate: 60,000 HU/min Housing heat capacity: 1,600,000 HU Anode diameter: 3.1 in Anode angle: 8.5 in (9-inch Image Intensifier) 10 in (12-inch Image Intensifier) X-ray tube cooling fan (Vascular, Neurovascular & Cardiac units) Collimator Iris collimation with dual opposing semi-transparent shutters allow elliptical, round and rectangular collimation Iris and shutters are continuously variable All functions remotely controlled from the C-Arm control panel Fluoroscopy Mode Focal spot: 0.3 mm kVp range: 40 - 120 kVp mA range: 0.2 - 5.0 mA normal mode mA range: 1.0 - 12 mA continuous fluoro boost mode Auto and manual modes Continuous, one-shot or pulsed operation ABS varies mA, kVp and camera gain User specific ABS tables Pulsed Fluoroscopy Mode Focal spot: 0.3 mm kVp range: 40 - 120 kVp mA range: 0.2 - 5.0 mA Pulse rate: 1, 2, 4, or 8 pulses per second Pulse width: 30 or 50 milliseconds Computer controlled ABS, mA, kVp and camera gain Pulsed Fluorography Mode (optional) Focal spot: 0.3 mm kVp range: 40 - 120 kVp mA range: 0.2 - 40.0 mA Pulse rate: 1, 2, 4, or 8 pulses per second Pulse width: 30 or 50 milliseconds Computer controlled ABS, mA, kVp and camera gain Digital Spot Mode (optional) Standard with the Expanded Surgical Platform (ESP) Enhanced digital fluorographic one-shot with 12 mA boost Automatically terminates exposure and stores enhanced image to storage archival disk Radiographic Mode Focal spot: 0.3 mm or 0.6 mm Focal spot automatically selected 0.3 mm - mAs range: 1 - 100 mAs 0.6 mm - mAs range: 110 - 300 mAs kVp range: 50 - 120 kVp Video Imaging System Image Intensifier 9 in Image Intensifier Tri-mode 9 in / 6 in / 4.5 in image intensifier Minimum central resolution (at the monitor): 9 in.: 1.4 lp/mm 6 in.: 2.0 lp/mm 4.5 in.: 2.4 lp/mm DQE: 65% (typical) 12 in Image Intensifier (optional) Tri-mode 12 in / 9 in / 6 in image intensifier Minimum central resolution (at the monitor): 12 in: 1.0 lp/mm 9 in: 1.3 lp/mm 6 in: 1.6 lp/mm DQE: 65% (typical) Video Camera High resolution CCD camera Full frame capture 360° motorized rotation On-screen orientation indicator (real-time feedback without fluoro) Left-right image reversal Top-bottom image reversal Negative mode Video signal: Standard RS 170A 60 Hz, 525 lines Aspect ratio: 4:3 Computer controlled features: Gain Blanking Camera iris Video Monitors Dual 16 in square, black etched, anti-glare, anti-static 525 lines/frame - 512 pixels Ambient room light sensor Multi-LED X-ray "ON" indicator Remote window/level controls Hardcopy Options Thermal printer External DICOM box Image Capture Device Laser aiming device (optional) C-Arm Dimensions Height: 68 / 86 in (1734 / 2191 mm) Width: 33 in (838 mm) Length: 78 in (1994 mm) Weight: 720 lbs Workstation Dimensions Height: 64 in (1632 mm) Width: 27 in (692 mm) Depth: 27 in (692 mm) Weight: 430 lbs
Soma Technology, Inc offers a wide range of C-arms. If you have any questions about any of our C-arms or need a quick quote, call 1-800-GET-SOMA and one of our knowledgeable sales representatives will help you.
When the C-arm has been in storage for 60 days it will be detected by its internal clock. During the system startup after these 60 days you will get a message on the C-arm control panel screen to allow the C-arm to warm up for 4 hours.
When the C-arm has been in storage for 6 months it will also be detected by its internal clock. During the system startup after these 6 months, you will get a message on the c-arm control panel screen to allow the C-arm to recharge for 24 hours.
It is important to follow these instructions after getting one of these messages.