Bausch & Lomb Stellaris PC

Quotes in less than 24 hours Download Specifications

Bausch & Lomb Stellaris PC Features

The Bausch & Lomb Stellaris PC microsurgical system provides a high-performance experience in vitreoretinal and cataract eye surgeries. This system enables surgeons to perform different ophthalmic procedures while saving time, space, and money for the surgeons, and the patients. The Stellaris PC system has light-weight, ultra-high-speed vitrectomy probes for conventional and
transconjunctival vitrectomy.

  • Dual light source with surgeon-selected color filters.
  • Optimal platform for the smallest incisions for both retinal and cataract surgeries.
  • Capable of 1.8 mm MICS phacoemulsification.
  • Easily upgraded to take advantage of future technology evolutions.
  • 19” 5:4 aspect ratio color touchscreen display.
  • The system can be set for either gravity infusion or infusion using pressurized air.

Bausch & Lomb Stellaris PC Specifications

Dimensions

  • Height: 48 in (122 cm)
  • Width: 18 in (45.7 cm)
  • Depth: 18 in (45.7 cm)
  • Weight: 230 lbs (114 kg)

Display

  • Type: Flat Panel, TFT LCD Full Color
  • Size: 19” (48.2 cm) Diagonal
  • Pixels: 1280 x 1024
  • Tilt: +15° up and -10° down
  • Swivel: ±90°

Aspiration

  • General: Provides Cassette Full, Near-Full, and Continuous Fluid Level Sensing. Programmable vacuum response curves.
  • Modes of Operation: Linear control of vacuum. Fixed, On/Off control of the vacuum. Dual Linear Modes: Pitch or Yaw.
  • Operating Parameters: I/A mode: 0 mmHg to 600 mmHg; Phaco: 10 mmHg to 600 mmHg; Vitrectomy: 0 mmHg to 600 mmHg; Extrude: 0 mmHg to 600 mmHg; Vacuum Control: 1 mmHg increments

Irrigation

  • Gravity feed from I/V bottle with pinch valve On/Off control via foot pedal

Reflux

  • Control: Gravity feed from I/V bottle; Modes: Continuous, Pulsed; Activated via the Foot Control

Vitrectomy

  • Linear Cut Rate Mode Operating Parameters: Range: 30 to 5000 cuts per minute in 1 cut per minute increments; Control: Linear control of cut-rate via the foot pedal
  • Fixed Cut Rate Mode Operating Parameters: Range: 30 to 5000 cuts per minute in 1 cut per minute increments; Cut rate is derated no more than 20% above 3000 feet (915 meters) altitude; Control: On/Off control of cut via the foot pedal

Ultrasound Functions

  • Programming Levels 1,2,3
    • Continuous ultrasound
    • Pulsed ultrasound
    • Fixed pulse ultrasound
    • Single burst ultrasound
    • Multiple burst ultrasound
  • Programming Level 3 only
    • Dual Linear Ultrasound
    • Linear Power, Linear Pulse ultrasound
    • Linear Power, Linear Duty Cycle ultrasound
    • Dual Linear Multiple Burst ultrasounds
    • Variable Power Multiple Burst ultrasound
    • Variable Power Linear Burst ultrasound

Viscous Fluid Controls

  • Injection Mode Pressure: 70 psi (482.6 kPa, 4.8 bar)
  • Extraction Mode Vacuum: Between 5 to 600 mmHg in 10 mmHg increments

Fluid Air Exchange

  • Output: 0.1 micron hydrophobic filtered air
  • Pressure: 150 mmHg maximum air pressure
  • Flow Rate: Up to 4.8 standard cubic feet per hour (2.25 L/min)
  • Safety: The system includes a pneumatic shut-off valve in case of power loss

Illumination

  • Modes of Operation: Independent Illumination and control of either port
  • Lamp Type: Xenon and Xenon-Mercury
  • Output: Light output from a single port is a minimum of 25 lumens using a standard 20g probe.
  • Safety Filter: Both ports incorporate permanent filtration to reduce ultraviolet, violet, deep red, and infrared light
  • Control: 0-100% control range, 1% resolution
  • Color Filtration: None, Green, Yellow, Amber (only available on Port 1 when a xenon lamp is installed)