Monday Matchup

December 11, 2017
Monday Matchup

Medrad Stellant Injector Features

The Medrad Stellant CT injection system with Certegra Workstation delivers new levels of efficiency and patient-centered care in CT imaging. An integral part of Bayer’s CT imaging solution, the scalable informatics ready solution offers radiation dose management and Contrast Dose Management options complete with injector interfacing between the scanner, PACS, RIS, and speech recognition systems. With the support of CT solution with VirtualCare Remote Support and flexible support service programs to meet the changing needs.

Enhanced Protocol Management and Precision Timing

Our workflow-centralized interface gives technologists point of care tools to efficiently manage injection protocols for enhanced visualization in complex CT angiography and cardiac CT studies.

Enhanced Protocol Management

  • Storage and recall of up to 250 protocols.
  • Designed for complex CTA and Cardiac CT protocols.
  • Creates a tight contrast bolus.
  • Enables precisely timed contrast delivery.
  • Ability to add Certegra® P3T® 2.0 technology to drive personalized patient protocol standardization through new capabilities, including presets for radiologist-preferred protocols and the ability to save and recall P3T software protocols.

Dual Syringe Utilization Benefits

Uniform Enhancement

Clinical benefits of injecting contrast and saline at different ratios to visualize the whole heart. Clinical research has shown that simultaneous injection of contrast and saline, in user-selected ratios, can.

  • SProvide more uniform attenuation of the right and left ventricles.
  • Minimize artifacts by achieving proper attenuation levels.
  • Visualize the right coronary arteries and right ventricles in a single study by achieving more uniform attenuation.

Medrad Stellant Specifications

Injection Specifications

  • Flow Rate: 0.1 to 10 mL/sec on 0.1 mL increments
  • Volume: 1 mL to syringe capacity in 1 mL increments
  • Programmable Pressure Limit: 200 mL syringe: 325 psi, 2241 kPa
  • Scan Delay: 0-300 seconds (5 minutes) in 1 second increments
  • Pause: 1-900 seconds (15 minutes) in 1 second increments
  • Hold: Maximum HOLD time is 20 minutes
  • Syringes (Volume Capacity): 200 mL sterile disposable syringe
  • Maximum Number of Phases: 6
  • Maximum Number of Protocols: 250

General Specifications

  • Electrical Requirements: 100-240 VAC, 50/60 Hz, 300 Volts-AMPs
  • Syringe Heat Maintainer Range: 95 degrees F ± 9 degrees; 35 degrees C ± 5 degrees
  • Head Mounting Options: Overhead Counterpoise System of Floor Pedestal (Floor Pedestal includes an Integral IV Pole)
  • DualFlow: Simultaneous Injection of Contrast and Saline
  • Medrad XDS Extravasation Detection System: Extravasation Detector; Extravasation Detector Device
  • Certegra P3T Cardiac Application: Patient-specific Injection Protocols for Cardiac CTA
  • Certegra P3T Abdomen Application: Abdominal Protocol Optimization Software
  • Certegra P3T PA Application: Pulmonary Angiography Protocol Optimization Software

Mechanical Specifications

Dual Injector Head

  • Height: 6.1″ (15.5 cm)
  • Width: 12.1″ (30.7 cm)
  • Depth: 14.5″ (36.8 cm)
  • Weight: 17.9 lb (8.1 kg) (Without Syringe)

Base Unit

  • Height: 11.5″ (29.2 cm)
  • Width: 11.0″ (27.9 cm)
  • Depth: 8.8″ (22.2 cm)
  • Weight: 13.6 lb (6.2 kg)

Certegra Workstation (CWS)

  • Height: 13.5″ (34.2 cm)
  • Width: 15.8″ (40.0 cm)
  • Depth: 10.2″ (30.0 cm)
  • Weight: 17.6 lb (8.0 kg)

VS

 

Baxter Sigma Spectrum Features

The Baxter Sigma Spectrum Infusion System was designed with features to help reduce errors when programming an IV infusion. You have the option of choosing the Sigma Spectrum Infusion Pump, with software version 6.05 or the Baxter Sigma Spectrum with software version 6.02. For example, the Sigma Spectrum automatically defaults to using the drug safety library at the initial start of the system. Small, lightweight and easy-to-use, the Sigma Spectrum Infusion System also offers wireless connectivity to integrate data into a hospital’s EMR system and facilitate the transfer of data to and from the system for updating drug libraries as well as for continuous quality improvement reports.

Multiple Prevention Systems

  • Configurable dose error reduction software
  • Single step titration limit
  • Check flow at start of infusion
  • Secondary container infusion check

Comprehensive log software to create CQI reports Rapid, Intuitive Work-flow

  • Easy to set-up and program safely
  • Bright, easy to read color display
  • Use of Baxter’s standard IV administration sets
  • Quick drug find library search

Economic Value

  • Utilizes Baxter’s standard IV administration sets to help reduce set up time and waste
  • Facilitates easy training of staff

Baxter Sigma Spectrum Specifications

Dimensions

  • With Standard Battery
    • Without IV Pole Clamp
      • Height: 5.8 In (14.73 cm)
      • Width: 4.2 In (10.67 cm)
      • Depth: 2.5 In (6.35 cm)
      • Weight: 1.6 lbs ± 0.06 lbs (25.5 oz ± 1 oz)
    • With IV Pole Clamp
      • Height: 5.8 In (14.73 cm)
      • Width: 6.4 In (16.26 cm)
      • Depth: 4.7 In (11.94 cm)
      • Weight: 2.1 lbs ± 0.06 lbs (33.5 oz ± 1 oz)
  • With Wireless Battery Module
    • Without IV Pole Clamp
      • Height: 6.3 In (16 cm)
      • Width: 4.2 In (10.67 cm)
      • Depth: 2.5 In (6.35 cm)
      • Weight: 1.7 lbs ± 0.06 lbs (26.5 oz ± 1 oz)
    • With IV Pole Clamp
      • Height: 6.3 In (16 cm)
      • Width: 6.4 In (16.26 cm)
      • Depth: 4.7 In (11.94 cm)
      • Weight: 2.2 lbs ± 0.06 lbs (34.5 oz ± 1 oz)

Pumping Mechanism

  • Linear peristaltic

Infusion Modes

  • Primary and Secondary, Multi-Step, and Cyclic TPN

Total Volume

  • 0.1 to 999 mL with 0.1 mL increments from 0.1 to 99.9 mL and 1.0 mL increments from 100 to 999 mL

Flow Rate

  • 0.5 to 999 mL/hr with 0.1 mL/hr increments from 0.5 to 99.9 mL/hr and 1.0 mL/hr increments from 100 to 999 mL/hr

Max Pump Pressure

  • 28 PSI

Occlusion Pressure

  • Adjustable: High (19 ±9 PSI), Medium (13 ±6 PSI), and Low (6 ±4 PSI)

 

Which Monday Matchup are you choosing?

Leave a Reply

Your email address will not be published. Required fields are marked *

Explore Other Blog Items By Category