GE Optima XR220amx
24-Hour QuotesPricing up to 50% below the cost of new,
with service and warranty included. Download Specifications
GE Optima XR220amx Features
The Optima XR220amx is a self-contained battery-operated mobile radiographic digital X-ray imaging system designed for performing radiographic exams at the point of care when it is not safe or practical to move the patient to the radiographic room.
Optima XR220amx is suited for routine radiographic procedures within a hospital including radiology departments, intensive care units, cardiac care units, emergency departments, operating rooms, orthopedics, pediatrics, hospital rooms, and clinics.
- FlashPad Lightweight detector designed for mobile use weighs less than 4.5 kg (10 lbs.) including battery
- “Stand-by” mode eliminates boot-up cycles and allows exposure within 25 seconds
- Designed for 24/7 availability. Use with battery or make and process exposures while the unit is charging
- The detector can support up to 160 Kg (352 lbs.) of distributed load for bariatric applications
- The detector battery charges automatically while the detector is in the bin
- Automatic charging algorithms allow the system to be re-charged even if batteries are not fully drained
- 15kW (nominal) generator and available 30kW(nominal) option
GE Optima XR220amx Specifications
Wireless Digital Detector
- Detector battery can take up to 50 exposures per hour and provide enough power for 3 hours of use on a single charge
- Single panel (non-tiled) amorphous silicon detector with a Cesium Iodide scintillator
- Image area: 40.4 cm x 40.4 cm (15.9 in x15.9 in)
- Active matrix: 2024 x 2024 pixels
- Pixel Pitch: 200 microns
- Typical upper dynamic range: 7.8mR
- Typical DQE: @ 0lp/mm: 68%)
- Two handgrips
Detector Environmental Conditions
Temperature
- Operating: 15°C to 35°C
- Non-Operating: -0°C to 50°C (maximum change 20°C per hour)
Humidity
- Operating: 10% to 80% RH, noncondensing(max. change 30% per hour)
- Non-Operating: 10% to 95% RH, noncondensing (max. change 30% per hour)
Power
- Capable of 100-240 V nominal, 50/60 Hz operation
- System battery status display
X-Ray Source
- Nominal Tube Voltage (Radiographic) 40 ~ 150 kV
- Nominal Focal Spot size (IEC 60336):
- Large Focus: 1.2 mm
- Small Focus: 0.6 mm
- Anode Rotation Speed (minimal): 3200 min-1
- Permanent Filtration: 0.9 mm Al/75 kV IEC60522: 1999
- Maximum X-ray Tube Current
- Large Focus: 500 mA
- Small Focus: 200 mA
- Maximum Continuous Heat Dissipation: Without Air-circulator: 170 W (238 HU/s)
- Maximum anode heat units: 140 kHU
- Exposure time: 4.0 msec – 6.0 sec