{"id":32450,"date":"2025-08-19T16:30:50","date_gmt":"2025-08-19T20:30:50","guid":{"rendered":"https:\/\/www.somatechnology.com\/spanish\/?p=32450"},"modified":"2026-01-03T01:30:24","modified_gmt":"2026-01-03T06:30:24","slug":"equipos-compatibles-con-mri","status":"publish","type":"post","link":"https:\/\/www.somatechnology.com\/spanish\/2025\/08\/19\/equipos-compatibles-con-mri\/","title":{"rendered":"Compatibilidad con Resonancia Magn\u00e9tica (MRI): Materiales Seguros, Pruebas y Normativas"},"content":{"rendered":"<ol>\n<li><a href=\"#1\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">What is an MRI?<\/span><\/span><\/span><\/span><\/a><\/li>\n<li><a href=\"#2\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">What are the safety standards for an MRI machine?<\/span><\/span><\/span><\/span><\/a><\/li>\n<li><a href=\"#3\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">How are MRI safety tests performed?<\/span><\/span><\/span><\/span><\/a><\/li>\n<li><a href=\"#4\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">Are MRI batteries compatible?<\/span><\/span><\/span><\/span><\/a><\/li>\n<li><a href=\"#5\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">Final Thoughts<\/span><\/span><\/span><\/span><\/a><\/li>\n<\/ol>\n<h3 id=\"1\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">What is an MRI?<\/span><\/span><\/span><\/span><\/h3>\n<p><span data-preserver-spaces=\"true\"><a href=\"https:\/\/my.clevelandclinic.org\/health\/diagnostics\/4876-magnetic-resonance-imaging-mri\" target=\"_blank\" rel=\"noopener\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">MRI stands for magnetic resonance imaging<\/span><\/span><\/span><\/span><\/a><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"> . It is a medical tool that uses powerful magnets, radio waves, and a computer to see inside the human body, especially in soft tissue areas like the brain and muscles. Unlike X-rays or computed tomography (CT) scans, an MRI does not use radiation. Although this means it is safer than X-rays and CT scans because it avoids radiation exposure, it does not mean it is risk-free.<\/span><\/span><\/span><\/span><\/span><\/p>\n<h3 id=\"2\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">What are the safety standards for an MRI machine?<\/span><\/span><\/span><\/span><\/h3>\n<p><span data-preserver-spaces=\"true\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">Since MRIs use powerful magnets, items brought into MRI rooms must be carefully labeled for safety reasons. These labels follow strict ASTM <\/span><\/span><\/span><\/span><a href=\"https:\/\/www.astm.org\/news\/promoting-safe-use-mri-technology-ma12\" target=\"_blank\" rel=\"noopener\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">and<\/span><\/span><\/span><\/span><\/a><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"> FDA <\/span><\/span><\/span><\/span><a href=\"file:\/\/\/Users\/somatechintl\/Downloads\/Testing-Labeling-MRI-Envrionment-Guidance.pdf\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">guidelines<\/span><\/span><\/span><\/span><\/a><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"> and divide equipment into three categories:<\/span><\/span><\/span><\/span><\/span><\/p>\n<ul>\n<li><strong><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">MRI Safe<\/span><\/span><\/span><\/span><\/strong><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"> : These devices pose no known risks in MRI rooms because they contain no metallic or conductive parts. The FDA and ASTM note that MRI Safe devices are made of nonmetallic, nonconductive, and nonmagnetic materials.<\/span><\/span><\/span><\/span>\n<ul>\n<li><strong><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">Examples<\/span><\/span><\/span><\/span><\/strong><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"> : plastics, wood, glass, most ceramics and composites, and nonmetallic fabrics.<\/span><\/span><\/span><\/span><\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p><img decoding=\"async\" class=\"wp-image-29621 aligncenter\" src=\"https:\/\/www.somatechnology.com\/wp-content\/uploads\/2025\/08\/MRI_Safe-300x300.jpg\" alt=\"\" width=\"220\" height=\"220\" title=\"\"><\/p>\n<ul>\n<li><span data-preserver-spaces=\"true\"><strong><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">MRI Conditional:<\/span><\/span><\/span><\/span><\/strong><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"> These devices are safe only under specific conditions, such as a maximum field strength value, absorption rate, or other parameters. They may contain metal or electronic components, but require extensive testing, and the label must clearly specify the permitted conditions.<\/span><\/span><\/span><\/span><\/span>\n<ul>\n<li><strong><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">Examples<\/span><\/span><\/span><\/span><\/strong><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"> : titanium, aluminum, brass, copper, gold, or certain stainless steels.<\/span><\/span><\/span><\/span><\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p><img decoding=\"async\" class=\"wp-image-29620 aligncenter\" src=\"https:\/\/www.somatechnology.com\/wp-content\/uploads\/2025\/08\/MRI_Cond-300x300.jpg\" alt=\"\" width=\"220\" height=\"220\" title=\"\"><\/p>\n<ul>\n<li><span data-preserver-spaces=\"true\"><strong><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">MRI Unsafe:<\/span><\/span><\/span><\/span><\/strong><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"> These devices pose known risks and should never enter the MRI room. They contain ferromagnetic metals and alloys that react harshly to the magnetic field.<\/span><\/span><\/span><\/span><\/span>\n<ul>\n<li><strong><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">Examples<\/span><\/span><\/span><\/span><\/strong><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"> : iron, nickel, or cobalt, steel, oxygen tanks, and jewelry<\/span><\/span><\/span><\/span><\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p><img decoding=\"async\" class=\"wp-image-29622 aligncenter\" src=\"https:\/\/www.somatechnology.com\/wp-content\/uploads\/2025\/08\/MRI_Unsafe-300x300.jpg\" alt=\"\" width=\"220\" height=\"220\" title=\"\"><\/p>\n<h3 id=\"3\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">How are MRI safety tests performed?<\/span><\/span><\/span><\/span><\/h3>\n<p><span data-preserver-spaces=\"true\"><a href=\"https:\/\/store.astm.org\/f2503-23e01.html\" target=\"_blank\" rel=\"noopener\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">The FDA explicitly recommends following the ASTM F2503<\/span><\/span><\/span><\/span><\/a><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"> labeling standard <\/span><\/span><\/span><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">. But how does F2503 determine each categorization? The equipment needs to pass several tests, including:<\/span><\/span><\/span><\/span><\/span><\/p>\n<ul>\n<li><a href=\"https:\/\/store.astm.org\/f2052-21.html\" target=\"_blank\" rel=\"noopener\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">ASTM F2052<\/span><\/span><\/span><\/span><\/a><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"> : Measures magnetically induced displacement force.<\/span><\/span><\/span><\/span>\n<ul>\n<li><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">Determines how much the MRI magnet can attract an object.<\/span><\/span><\/span><\/span><\/li>\n<\/ul>\n<\/li>\n<li><a href=\"https:\/\/store.astm.org\/f2119-24.html\" target=\"_blank\" rel=\"noopener\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">ASTM F2119:<\/span><\/span><\/span><\/span><\/a><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"> Evaluates artifacts in the MRI image.<\/span><\/span><\/span><\/span>\n<ul>\n<li><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">Determines if the object distorts or interferes with the MRI image (if it causes blurry spots, shadows, or other artifacts).<\/span><\/span><\/span><\/span><\/li>\n<\/ul>\n<\/li>\n<li><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">A <\/span><\/span><\/span><\/span><a href=\"https:\/\/store.astm.org\/f2182-19e02.html\" target=\"_blank\" rel=\"noopener\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">STM F2182<\/span><\/span><\/span><\/span><\/a><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"> : Measures RF-induced heating.<\/span><\/span><\/span><\/span>\n<ul>\n<li><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">Determines how much the object heats up due to the MRI radio waves.<\/span><\/span><\/span><\/span><\/li>\n<\/ul>\n<\/li>\n<li><a href=\"https:\/\/store.astm.org\/f2213-17.html\" target=\"_blank\" rel=\"noopener\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">ASTM F2213<\/span><\/span><\/span><\/span><\/a><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"> : Measures magnetically induced torque.<\/span><\/span><\/span><\/span>\n<ul>\n<li><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">Determines if an object experiences twisting or turning under the influence of the magnetic field<\/span><\/span><\/span><\/span><\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<h3 id=\"4\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">Are MRI batteries compatible?<\/span><\/span><\/span><\/span><\/h3>\n<p><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">The <\/span><\/span><\/span><\/span><strong><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">magnetic field<\/span><\/span><\/span><\/span><\/strong><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"> in MRIs is so strong that even batteries inside medical equipment must be properly labeled. In general, the batteries contain nickel, and their steel casings make them MRI-unsafe. However, MRI-safe and MRI-conditional batteries exist. These are usually lithium-ion or lithium-polymer batteries with aluminum or polymer casings. Both aluminum and most lithium compounds are nonmagnetic, so the MRI magnet does not exert a significant attraction on the battery pack.<\/span><\/span><\/span><\/span><\/p>\n<h3><span data-preserver-spaces=\"true\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">Common <\/span><\/span><\/span><\/span><\/span><span data-preserver-spaces=\"true\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">equipment found on MRI Suites<\/span><\/span><\/span><\/span><\/span><\/h3>\n<h5><a href=\"https:\/\/www.somatechnology.com\/stainless-steel\/poles-stands-hampers\/mayo-stands\/axia-mayo-stand?utm_source=blog&amp;utm_medium=blog&amp;utm_campaign=mri_compability\"><span data-preserver-spaces=\"true\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">Mayo Tables<\/span><\/span><\/span><\/span><\/span><\/a><\/h5>\n<h4><a href=\"https:\/\/www.somatechnology.com\/stainless-steel\/poles-stands-hampers\/mayo-stands\/axia-mayo-stand?utm_source=blog&amp;utm_medium=blog&amp;utm_campaign=mri_compability\"><span data-preserver-spaces=\"true\"><img decoding=\"async\" class=\"alignnone wp-image-15556\" src=\"https:\/\/www.somatechnology.com\/wp-content\/uploads\/2023\/06\/Axia-Mayo-Stands-300x300.png\" alt=\"Axia Mayo stands - Soma Tech Intl\" width=\"220\" height=\"220\" title=\"\"><\/span><\/a><\/h4>\n<h5><a href=\"https:\/\/www.somatechnology.com\/spanish\/equipo-medico-usado-remanufacturado\/maquinas-de-anestesia\/maquina-de-anestesia-aestiva-5-mri\/?utm_source=blog_spa&amp;utm_medium=blog&amp;utm_campaign=mri_compability\"><span data-preserver-spaces=\"true\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">Anesthesia Machines\u00a0<\/span><\/span><\/span><\/span><\/span><\/a><\/h5>\n<p><a href=\"https:\/\/www.somatechnology.com\/anesthesia-machines\/ge-datex-ohmeda-aestiva-5-mri\/\"><img decoding=\"async\" class=\"alignnone wp-image-16337\" src=\"https:\/\/www.somatechnology.com\/wp-content\/uploads\/2023\/09\/GE-Datex-Ohmeda-Aestiva-5-MRI-Anesthesia-Machine-300x300.jpg\" alt=\"GE Datex Ohmeda Aestiva 5 MRI Anesthesia Machine - Soma Tech Intl\" width=\"220\" height=\"220\" title=\"\"><\/a><\/p>\n<h5><a href=\"https:\/\/www.somatechnology.com\/spanish\/equipo-medico-usado-remanufacturado\/monitores-de-signos-vitales\/monitores-multiparametros\/philips-expression-mr400\/?utm_source=blog_spa&amp;utm_medium=blog&amp;utm_campaign=mri_compability\"><span data-preserver-spaces=\"true\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">Multiparameter Monitor\u00a0<\/span><\/span><\/span><\/span><\/span><\/a><\/h5>\n<h3><a href=\"https:\/\/www.somatechnology.com\/spanish\/equipo-medico-usado-remanufacturado\/monitores-de-signos-vitales\/monitores-multiparametros\/philips-expression-mr400\/?utm_source=blog_spa&amp;utm_medium=blog&amp;utm_campaign=mri_compability\"><img decoding=\"async\" class=\"alignnone wp-image-25988\" src=\"https:\/\/www.somatechnology.com\/wp-content\/uploads\/2019\/09\/Philips-Expression-MR400-patient-monitor-296x300.jpg\" alt=\"Philips Expression MR400 Patient Monitor\" width=\"216\" height=\"219\" title=\"\"><\/a><\/h3>\n<h3 id=\"5\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">Final Reflection<\/span><\/span><\/span><\/span><\/h3>\n<p><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">MRI compatibility is not just about bringing equipment into the exam room. It&#8217;s about safety, preserving image quality, and adhering to strict standards. Choosing MRI-compatible solutions from a trusted refurbishment partner like Soma means receiving:<\/span><\/span><\/span><\/span><\/p>\n<ul>\n<li><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">Equipment tested to ASTM and IEC standards.<\/span><\/span><\/span><\/span><\/li>\n<li><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">Solutions that maintain clear, distortion-free MRI images while protecting patients and staff from magnetic hazards<\/span><\/span><\/span><\/span><\/li>\n<li><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">The confidence that every component\u2014whether it&#8217;s anesthesia equipment, a patient monitor, or an accessory\u2014has been evaluated for both performance and safety in high-field MRI environments.<\/span><\/span><\/span><\/span><\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>What is an MRI? What are the safety standards for an MRI machine? How are MRI safety tests performed? Are MRI batteries compatible? Final&#8230;<\/p>\n","protected":false},"author":34,"featured_media":32454,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_relevanssi_hide_post":"","_relevanssi_hide_content":"","_relevanssi_pin_for_all":"","_relevanssi_pin_keywords":"","_relevanssi_unpin_keywords":"","_relevanssi_related_keywords":"","_relevanssi_related_include_ids":"","_relevanssi_related_exclude_ids":"","_relevanssi_related_no_append":"","_relevanssi_related_not_related":"","_relevanssi_related_posts":"","_relevanssi_noindex_reason":"","inline_featured_image":false,"footnotes":""},"categories":[137],"tags":[10989,10984,10988,10972,10990,10971,10986,10981,10983,10982,10975,10976,8793,10978,10977,10980,10979,10985,10987,10974,10973],"class_list":["post-32450","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-equipo-medico","tag-cumplimiento-de-seguridad-en-rm","tag-directrices-de-compatibilidad-con-rm","tag-dispositivos-medicos-para-rm","tag-equipo-compatible-con-irm","tag-equipo-compatible-con-mri","tag-equipo-compatible-con-rm","tag-equipo-no-ferromagnetico","tag-maquina-de-anestesia-para-rm","tag-materiales-seguros-para-rm","tag-monitor-de-paciente-para-rm","tag-mr-condicional","tag-mr-inseguro","tag-mri","tag-normas-de-seguridad-en-irm","tag-normas-de-seguridad-en-rm","tag-pruebas-astm-para-irm","tag-pruebas-astm-para-rm","tag-pruebas-de-equipos-para-rm","tag-seguridad-en-la-sala-de-rm","tag-seguro-para-irm","tag-seguro-para-rm"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.somatechnology.com\/spanish\/wp-json\/wp\/v2\/posts\/32450","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.somatechnology.com\/spanish\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.somatechnology.com\/spanish\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.somatechnology.com\/spanish\/wp-json\/wp\/v2\/users\/34"}],"replies":[{"embeddable":true,"href":"https:\/\/www.somatechnology.com\/spanish\/wp-json\/wp\/v2\/comments?post=32450"}],"version-history":[{"count":0,"href":"https:\/\/www.somatechnology.com\/spanish\/wp-json\/wp\/v2\/posts\/32450\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.somatechnology.com\/spanish\/wp-json\/wp\/v2\/media\/32454"}],"wp:attachment":[{"href":"https:\/\/www.somatechnology.com\/spanish\/wp-json\/wp\/v2\/media?parent=32450"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.somatechnology.com\/spanish\/wp-json\/wp\/v2\/categories?post=32450"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.somatechnology.com\/spanish\/wp-json\/wp\/v2\/tags?post=32450"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}