Criticare VitalCare 506N3 Features
Spot-check or continuously monitor three critical parameters with a single monitor. Designed to travel everywhere you do, the CriticareVitalCare 506N3 with integrated carrying handle attaches quickly and easily to roll stands. Available in multiple configurations, the VitalCare provides maximum versatility and cost-effectiveness.
Smart battery management allows up to 100 non-invasive blood pressure measurements on a single battery charge. With a compact design that is easily set up for spot-checks or continuous monitoring, the monitor adapts readily to hospital, clinic and transport requirements.
- ComfortCuff NIBP measures on-inflation for faster, more comfortable readings.
- Choice of CSI’s DOX or Nellcor OxiMax pulse oximetry.
- Audible and visual alarms are adjustable for use in continuous monitoring.
- Large responsive keys for fast spot-checks with easy to clean membrane keypad.
- Accommodates all patient types from adult to a neonate.
- Multi-patient trend memory.
- Rechargeable battery with direct AC power.
- Optional FILAC or Alaris TurboTemp predictive temperature for quick, accurate measurements.
- Optional integrated printer for on-demand, automatic interval, trends or multi-patient reports.
Criticare VitalCare 506N3 Specifications
Non-Invasive Blood Pressure
- Technique: Oscillometric measure upon inflation
- Measurement Time: <40 seconds typical; 0 to 300mmHg; standard adult cuff
- Automatic Measurement
- Cycles: 1 – 60 minute; 2 – 4 hour; STAT
- Inflation Pressure Range: 30 to 300mmHg (Adult); 30 to 150mmHg (Pediatric); 20 to 150mmHg (Neonate)
- Resolution: 1mmHg
- Clinical Accuracy: SP-10:2002
- Transducer Accuracy: ±2mmHg or ±2% of reading, whichever is greater, over a full range
- STAT mode: 5 minutes of consecutive readings
Pulse Oximetry
- Range: 1% to 99%
- Resolution: 1%
- Accuracy (DOX only): 70% to 99% range: ±2%; 50% to 69% range: ±3%; <50%: unspecified
- Accuracy (OxiMax Only): 70% to 99% range: ±2%; <70%: unspecified
- Method: Dual wavelength LED
- Audio: Tone with each detected pulse; pitch varies with saturation
Heart (Pulse) Rate
- Range: 20 to 300bpm
- Accuracy (DOX only): Greater of ±1bpm or ±1%, of reading
- Unspecified for <30 or >240 bpm
- Accuracy (OxiMax only): Greater of ±1bpm or ±1%, of reading
- Unspecified for <30 or >240 bpm
- Update Time: Every second
- Resolution: 1bpm
- Pulse Volume: 10 levels or Off
Alarms
- Indication: Audible; Visual
- Volume: 10 levels or Off
- Silence: Yes; 2 minutes or permanent
Trend Memory
- Memory: Last 24 hours
- Parameters: SpO2, pulse rate, NIBP, temperature
- Report Types: Single Patient or Multi-patient; Selectable formats
Displays
- Type: LED
- Parameters: NIBP, SpO2; temperature, pulse rate; pulse bar
- Status: Alarm Silence; Sensor; Low Battery; External
- Power; Patient Size
- Text: Alphanumeric LCD
- Languages: English, French, German, Italian, Portuguese, Spanis h, Dutch, Danish
System Output
- Com Port: Serial, RS 232-compatible
Printers
- Type: Thermal array
- Tabular Mode: 1 – 60-minute intervals; 2 – 24-hour intervals; Auto on BP; Auto on Alarm, Off
Mechanical
- Weight: Base unit with battery: 6.95 lb; 3.15kg
- Size: Base unit: 8.7” (H) x 7.1” (W) x 6.5” (D); 22cm (H) x 18c m (W) x 16.5cm (D)
- Com Port: Serial, RS 232-compatible
Power Requirements
- Voltage: 100 to 240 VAC, 50 to 60 Hz
- Battery: Sealed lead acid; Life: 8 hours
- Rechargeable: 6 hours
Environmental
- Operating Temperature: 32º to 113º F; 0º to 45º C
- Storage Temperature: 23º to 122º F; -5º to 50º C
- Operating Humidity: 15% to 90%, non-condensing
Classification
- Type of Protection: Class I equipment
- The degree of Protection: Type CF defibrillator-proof equipment
- Protection against Ingress: IPX1 rating, Drip-Proof Equipment