Axia i120
24-Hour QuotesPricing up to 50% below the cost of new,
with service and warranty included. Download Specifications
Axia i120 Features
The Axia i120 is an adult, pediatric, and neonatal patient monitor. The i120 has a 12.1-inch high-resolution touchscreen display and can measure 3 and 5-lead ECG, respiration rate, Spo2, pulse rate, NIBP, and temperature. Optional upgraded are available for 2-IBP, EtCO2, Nellcor SpO2, 12-lead ECG, SunTech NIBP, Cardiac output, and Cerebral state monitoring.
- 21.1” high-resolution touchscreen display
- Displays between 9 and 13 waveform traces
- Customizable NIBP measure cycles
- 3 or 5-lead ECG and optional 12-lead ECG
- Standard configuration ECG, Respiration, SpO2, PR, NIBP, and Temperature
Axia i120 Specifications
Dimensions
- Height: 13.15 in (33.4 cm)
- Width: 12.32 in (31.3 cm)
- Depth: 7 in (17.8 cm)
- Weight: 12.57 lb (5.7 kg)
Display
- Type: TFT Color Touchscreen
- Size: 12.1 in (13.73 cm)
ECG
- Input Dynamic Range: ±(0.5mVp~5mVp)
- Differential Input Impedance: ≥10MΩ
- Bandwidth: 0.05~150Hz (Dignostic); 0.5~40Hz (Monitoring); 1~20Hz (Operation)
- CMRR: ≥90dB (Diagnostic); ≥105dB (Monitoring & Operation)
- Sensitivity Selection: ×1/4, ×1/2, ×1, ×2, ×4 and Auto
- Sweeping Speed: 6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s
- HR Measuring Range: 15~350bpm
- HR Accuracy: ±1% or ±2bpm, whichever is greater
Respiration Rate
- Measuring Range: 0~120rpm
- Measuring Accuracy: ±5% or ±2 rpm, whichever is greater
NIBP
- Type: Oscillometric
- Typical Measurement Time: <30 seconds (adult cuff)
- NIBP measuring accuracy: Mean difference: ±5mmHg; Standard Deviation: 8mmHg
- NIBP Measurement Mode: Manual, Auto, STAT, Multi-cycle mode
- Auto Measuring Intervals: 1-480min
- NIBP measuring range
- SYS: 40~275mmHg (Adult); 40~200mmHg (Pediatric); 40~135mmHg (Neonate)
- DIA: 10~210mmHg (Adult); 10~150mmHg (Pediatric); 10~95mmHg (Neonate)
- MAP: 20~230mmHg (Adult); 20~165mmHg (Pediatric); 20~110mmHg (Neonate)
SpO2
- Type: Dual-wavelength optical
- Range: 0%~100%
- Accuracy: Arms is not greater than 2% for SpO2 range 70~100%.
- PR Range: 30~250bpm
- PR Accuracy: ±2bpm or ±2%, whichever is greater
- Low Perfusion Performance: As low as 0.3%.
Temperature
- Compliant: ISO 80601-2-56: 2017
- Range: 32-122°F (0-50°C)
- System Response Time: <150s
- Alarm Accuracy: ±0.1°C
- Accuracy
- Without Probe: In the range of 32-122°F (0-50°C), error is ±0.1 °C
- With Probe: In the range of 77-113°F (25-45°C), error is ±0.2°C
- In other ranges, error is ±0.4°C
Cerebral State Monitoring (CSM) (Optional)
- EEG sensitivity: ±400μV
- Noise Level: <2μVp-p, <0.4μV rms (1~250Hz)
- CMRR: >140dB
- Input impedance: >50Mohm
- CSI and Update: 0-100. filter: 6-42Hz, 1 sec. update
- EMG%: 0-100 (logarithmic), filter: 75-85 Hz, 1 sec. update
- BS%: 0-100. filter: 2-42 Hz, 1 sec. update
IBP (Optional)
- Type: Strain gauge transducer
- Input Sensitivity: 5μV/V/mmHg
- Measuring Range: -50~300mmHg
- Measuring Accuracy: ±2% or ±4mmHg, whichever is greater
- Measuring Positions: ART, RAP, PA, LAP, CVP; ICP, AUXP1, AUXP2
- Calibration: None
Cardiac Output (C.O.) (Optional)
- Blood temperature Range: 73-109°F (23-43℃); accuracy: ±0.9°F (±0.5℃)
- Injecta Temperature Range: 32-68°F (0-20℃), accuracy: ±0.9°F (±0.5℃)
- Measuring Range: 0.2~20 L/min
- Measuring Accuracy: ±0.2 L/min or ±10%, whichever is greater
EtCO2 (Optional)
- Type: Sidestream / Mainstream
- Range: 0-150 mmHg
- Sampling Rate (Sidestream): 50 ml/min fixed flow rate
- Response Time / Rise Time
- Sidestream
- Response time <9s
- Rise Time: <60ms
- Sidestream
- Warm-up Time
- Mainstream: Parameters can be displayed within 15s
- Sidestream: Parameters can be displayed within 20s