Bovie IDS 210
24-Hour QuotesPricing up to 50% below the cost of new,
with service and warranty included. Download Specifications
Bovie IDS 210 Features
The Bovie IDS 210 is a 200-watt high power, operating room generator, by Bovie. The unit incorporates the power and safety of a premium OR generator at significant savings to the medical facility. The system delivers 12 monopolar and bipolar RF energy modalities to provide a high level of surgical precision. Engineered with the safety of the patient in mind, the IDS-210 includes technology such as Bovie NEM return split pad contact quality monitoring, Bovie FDFS tissue sensing technology, self-test circuits, as well as specialized modalities for laparoscopic and delicate procedures.
- Two Cut Modes
- Four Levels of Blend
- Three Coagulation Modes
- Three Bipolar Modes
- Fast Digital Feedback System
- Three Front-Panel Accessory Connections and two rear-panel footswitch connections
Bovie IDS 210 Specifications
Dimensions
- Height: 6.5 In (16.5 cm)
- Width: 14.75 In (37.5 cm)
- Depth: 18.1 In (46 cm)
- Weight: < 20 lbs (< 9.07 kg)
General
- Contact Monitoring Systems: BovieNEM
- Contact Monitoring Systems
- Range/Trip Point: 10 ohms or less over entire
- operating range (10C° to 40°C)
- Cooling System: Passive Cooling
- Technology: Isolated RF Output
- Pre-set Feature: Yes
- Monopolar HP Ports: 2
- Dual Activation Tone Alert: Yes
- Connector Ports/Power Switch: White
- Power Display Accuracy: ± 20% or 5 watts whichever is greater
Bipolar
- Macro Bipolar
- Watts: 80
- VPeak Max Voltage: 600V
- Crest Factor (Typical): 1.5 ± 20%
- Frequency: 490 kHz ± 4.9 kHz
- Micro Bipolar
- Watts: 80
- VPeak Max Voltage: 500V
- Crest Factor (Typical): 1.5 ± 20%
- Frequency: 490 kHz ± 4.9 kHz
- Standard Bipolar
- Watts: 50
- VPeak Max Voltage: 250V
- Crest Factor (Typical): 1.5 ± 20%
- Frequency: 490 kHz ± 4.9 kHz
Monopolar
- Cut I
- Watts: 200
- VPeak Max Voltage: 1000V
- Crest Factor (Typical): 1.7 ± 20%
- Frequency: 490 kHz ± 4.9 kHz
- Cut II
- Watts: 200
- VPeak Max Voltage: 750V
- Crest Factor (Typical): 1.7 ± 20%
- Frequency: 490 kHz ± 4.9 kHz
- Blend (1)
- Watts: 200
- VPeak Max Voltage: 1320V
- Crest Factor (Typical): 1.8 ± 20%
- Frequency: 490 kHz ± 4.9 kHz
- Blend (2)
- Watts: 200
- VPeak Max Voltage: 1475V
- Crest Factor (Typical): 2.0 ± 20%
- Frequency: 490 kHz ± 4.9 kHz
- Blend (3)
- Watts: 200
- VPeak Max Voltage: 1650V
- Crest Factor (Typical): 2.2 ± 20%
- Frequency: 490 kHz ± 4.9 kHz
- Blend (4)
- Watts: 200
- VPeak Max Voltage: 1870V
- Crest Factor (Typical): 2.4 ± 20%
- Frequency: 490 kHz ± 4.9 kHz
- Pinpoint Coagulation
- Watts: 120
- VPeak Max Voltage: 1800V
- Crest Factor (Typical): 3.1 ± 20%
- Frequency: 490 kHz ± 4.9 kHz
- Spray Coagulation
- Watts: 120
- VPeak Max Voltage: 4000V
- Crest Factor (Typical): 6.0 ± 20%
- Frequency: 350 to 450 kHz
- Gentle Coagulation
- Watts: 120
- VPeak Max Voltage: 450V
- Crest Factor (Typical): 1.6 ± 20%
- Frequency: 490 kHz ± 4.9 kHz