GE Dinamap Procare 400 Features

The GE DINAMAP ProCare 400 Vital Signs Monitor enhances productivity with easy to use features and an intuitive menu structure. With a properly-sized BP cuff in place, just press a button to take a BP reading. It’s that easy! Comprehensive – One monitor for the entire range of patient populations – Neonatal, Pediatric, & Adult.
Additional GE DINAMAP ProCare 400 Features: NIBP, Temp, Pulse Rate, and SpO2 along with a built in Pole Mount. The GE DINAMAP ProCare 400 Includes NIBP Hose and Adult Cuff (New), SpO2 sensor, Oral Temp Sensor, New Battery, Manual, and comes with a 6 Months Parts and Labor Warranty. See below for more information.

  • Large digital displays give you readings at a glance.
  • One button press provides accurate BP reading.
  • Simple menus for customized settings.
  • Built in recorder Massimo or Nellcor SpO2 for the 400 series
  • Battery back up.

GE Dinamap ProCare 400 Specifications

Dimensions

  • Size: 2.4˝ x 7.1˝ x 8.9˝ (6 cm x 18 cm x 22 cm) D x H x WHeight: 9.7” (24.7 cm). Width: 8.6” (21.9 cm) without tempera- ture, 10” (25.4 cm) with temperature. Depth: 5.3” (13.5 cm)
  • 5.68 lbs (2.58 kg) including battery

Blood Pressure

  • Cuff pressure range: 10 to 290 mmHg (adult/ped); 10 to 140 mmHg (neonate).
  • Blood pressure accuracy: meets or exceeds ANSI/AAMI standard SP-10 (mean error ≤5mmHg, standard deviation ≤8 mmHg.
  • Maximum determination time: 120 seconds (adult/ped) and 85 seconds (neonates).
  • Overpressure cutoff: 330 mmHg (adult/ped) and 165 mmHg (neonate).
  • Pulse rate range: 30 to 200 beats/min (adult/ped) and 30 to 220 beats/min (neo- nate).
  • Pulse rate accuracy: ±3.5%. Systolic limits (mmHg): 200 high and 80 low.
  • Diastolic limits(mmHg): 120 high and 30 low.
  • Inflation pressure: 160 mmHg (adult/ped) and 110 mmHg (neonate).
  • Cycle button: 15

Sp02

  • SpO2 measurement range: 10 to 100%.
  • Pulse rate measurement range: 20 to 250 beats/min.
  • Accuracy and motion tolerance: adult without motion: 70 to 100% ±2 digits; neonate without motion: 70 to 100% ±3 digits; adult and neonate with motion: 70 to 100% ±3 digits.
  • Low perfusion: 70 to 100% ±2 digits, 0 to 69% unspecified.
  • Pulse rate without motion: 20 to 250 beat/min ±3 digits.
  • Pulse rate with motion: normal physiologic range 55 to 125 beats/min ±5 digits.
  • Pulse rate low perfusion: 20 to 250 beats/min ±3 digits

Pulse Rate

  • High: 150
  • Low: 50

Temperature

  • Scale: Fahrenheit (F) and Celsius(C).
  • Predictive mode range: 41.1°C and 106.0°F maximum and 35.6°C and 96.0°F.
  • Moni- tor mode range: 41.1°C and 106.0°F maximum and 26.7°C and 80.0°F minimum.
  • Monitor mode accuracy: ±0.1°C; 0.2°F (when tested in a calibrated liquid bath).
  • Determination time: approxi- mately 10 seconds, typical.