Criticare Poet IQ2 8500Q

24-Hour Quotes

Pricing up to 50% below the cost of new,
with service and warranty included.
Download Specifications

Criticare Poet IQ2 8500Q Features

The Criticare Poet IQ2 8500Q agent gas monitor measures real-time concentrations of anesthetic agent gases. The device measures gases using a sidestream method. The primary module measures concentrations of CO2, N2O, and five halogenated anesthetic agents. The Poet IQ2 8500Q monitor can also measure oxygen concentrations using a galvanic cell. It comes standard with a color TFT screen with three three-waveform displays.

  • Integrated CO2/agent detector.
  • Measures carbon dioxide, nitrous oxide, and five halogenated anesthetic agents.
  • Uses proprietary High IQ technology to identify and quantify agent gases.
  • No moving parts.
  • Reduced size.
  • Reliable.

Criticare Poet IQ2 8500Q Specifications

Dimensions

  • Height: 6.5” (16.5 cm)
  • Width: 11” (27.9 cm)
  • Depth: 12” (30.4 cm)
  • Weight: 13 lb (5.9 kg)

Pneumatics

  • Method: Sidestream; non-dispersive infrared
  • Sample Line: For use with 8 feet, PVC or PE
  • Occlusion Clearing: Automatic, as needed
  • Sound Pressure of Pneumatics: Automatic, as needed
  • Units (CO2): mmHg; Percent; kPa; Torr
  • Units (O2, N2O, Agents): Volume Percent
  • Calibration: Auto-calibrating, Manual Calibration
  • Flow Rate: 100 ml/min, 150ml/min, or 200ml/min, User Selectable

Display

  • Screen: 5.5” active color TFT display area (internal display)
  • Resolution: Internal Screen, 320 x 240 pixels External video output, 640 x 480 pixels
  • Waveforms: 3, maximum
  • Waveform Display Gain: 0.5×, 1×, 2×, 4× user selectable
  • Waveform Sweep Speed: 6.25, 12.5, 25 or 50 mm/sec, selectable

Controls

  • Keys: 7; membrane-activated
  • Rotary knob: Push and rotate; 24 steps/turn

Outputs

  • Com Ports: Digital DB9 (COM 1); Mini-DIN8 (COM 2)
  • Analog Output: mini-DIN8, Selectable waveform output
  • Video Port: Serial VGA Compatible
  • Waveforms available: O2, CO2, Agent, and N2O

Startup Times

  • To Respiration and Waveforms: 1 minute (±5 seconds)
  • To ET CO2 Waveforms: 1 minute (±5 seconds)
  • To Agent Concentrations: <5 minutes, partial accuracy; 20 minutes full

Respiratory Rate

  • Numeric Output: Yes
  • Source: Capnogram
  • Range: 1-100 breaths per minute
  • Accuracy: ±2 breaths per minute

N2O Compensation

  • Range: 0 to 99 vol%
  • Resolution: 1%
  • Accuracy: ±(1.5% abs + 4% rel) for breath rates up to 60 breaths/minute
  • Identification Threshold: 5% (for single and mixed agents)
  • Response Time: 2.5 seconds
  • Rise Time: (10-90%) 400 milliseconds
  • Display: Numerical Inspired N2O, Expired N2O, N2O Waveform

Oxygen Monitoring (O2)

  • Display: Inspired O2, expired O2 Numerical values, Waveform
  • Method: Oxidation-reduction galvanic cell
  • Range: 0-100%
  • Resolution: 1%
  • Accuracy: ± 3 vol% (0-90%), ±4 vol% (91-99%) for breath rates up to 60 breaths/minute
  • System Response Time: 1.5 seconds
  • Rise Time: (10-90%) 600 milliseconds @ 150 ml/min

CO2

  • Range: 0 to 99 mmHg, 0 to 12.5%, 0 to 12.5 kPa, 0 to 99 Torr
  • Display: Inspired CO2, Expired CO2 (End-Tidal) Numerical values, capnogram, and breath by breath ETCO2 bar graph
  • Waveform Scale: Selectable, percent only 0 to 3.13, 6.25, 12.5 or 25%
  • Resolution: 1 mmHg, 0.1%, 0.1 kPa, 1.0Torr
  • Accuracy: ± 2 % or 4% of reading for breath rates up to 60 breaths/minute
  • Flow Rate: 100, 150, 200 ml/min, user selectable

Halogenated Agents

  • Resolution: 0.1 Volume Percent
  • Range
    • Halothane; 0 to 10.0 vol. %
    • Isoflurane; 0 to 10.0 vol. %
    • Enflurane; 0 to 10.0 vol. %
    • Desflurane; 0 to 20.0 vol. %
    • Sevoflurane; 0 to 10.0 vol. %
  • Accuracy (Single Agent): ± (0.1% abs. + 4% of reading) for breath rates up to 60 breaths/minute
  • Identification Time for Single Agent: <15 seconds @ 200 ml/min
  • Identification Threshold
    • Halothane; 0.2 vol. %
    • Isoflurane; 0.3 vol. %
    • Enflurane; 0.3 vol. %
    • Desflurane; 0.3 vol. %
    • Sevoflurane; 0.3 vol. %
  • Mixed Gas Threshold: 0.2 vol. % + 10% of total concentration
  • Primary Agent Identification: User Selectable or Automatic
  • Mixed Agent Identification: Automatic (secondary agent)
  • Rise Time: 450 msec. for (10-90%) at 150 ml/min
  • Response Time: 2.5 seconds
  • Warm-up Time: 1 minute to first waveforms < 20 minutes to full accuracy
  • Auto Zeroing: Occurs 30 to 60 minutes
  • Duration 3.0 to 7.0 seconds
  • Display: Primary agent inspired and expired numerical values, Numerical values for five agents, Primary agent waveform, Secondary (mixed) agent numerical values
  • Effect of Interfering Gases
    • Ethyl alcohol: Negligible
    • Metabolic ketones, Acetone: Negligible
    • Carbon dioxide: Negligible
    • Nitrous oxide: Negligible
    • Helium: Negligible
    • Ether: Contraindicated
    • Cyclopropane: Contraindicated
    • Methoxyflurane: Contraindicated

Refurbished Criticare Poet IQ2 8500Q Agent Monitor

Soma Tech Intl offers Criticare Poet IQ2 8500Q Agent Monitor up to 50% below OEM prices with the same service and warranty as new. The Criticare Poet IQ2 8500Q is not only technically refurbished but also cosmetically refurbished to make it work and look like new. When the refurbishing process starts on the agent monitor, it is carefully inspected and tested by our own in-house biomedical engineers who are highly skilled and certified to work on surgical tables. If necessary, parts are replaced to make sure that all aspects of the Criticare Poet IQ2 8500Q are functioning properly. Once everything is in working order, the unit is calibrated back to the original engineering manufacturer’s specifications. This ensures that the unit is working the same way that it originally left the manufacturer. After the Criticare Poet IQ2 8500Q agent monitor is working like new it undergoes a special cosmetic restoration process. The Criticare Poet IQ2 8500Q is cleaned, minor scratches and dents are repaired, it’s painted, and new decals are replaced if necessary. After this strenuous refurbishing process, the Unit functions and looks like new. Soma Tech Intl is ISO 13485 certified and ensures that the best quality is given to all capital medical equipment that they sell. Before the Criticare Poet IQ2 8500Q is labeled patient-ready and packed up for shipment, it goes through one last quality control test that makes sure all aspects are again working as they should. If you are looking to buy a refurbished Criticare Poet IQ2 8500Q agent monitor contact soma at [email protected] or call us at 1-800-GET-SOMA.

Soma Tech Intl is also actively looking to purchase a Criticare Poet IQ2 8500Q If you or your facility is looking to sell your Criticare Poet IQ2 8500Q agent monitor be sure to contact Soma Tech Intl. Soma has a dedicated and experienced purchasing department that helps you through the entire process. Selling your used or pre-owned Criticare Poet IQ2 8500Q to Soma Tech Intl takes out the middle man in the equation. This also ensures that your medical facility gets top dollar for your equipment. Soma is 100% HIPPA compliant and makes sure that your equipment gets to our facility in the same condition that it left yours. Soma Tech Intl also gives the option for trade-in credit on your medical equipment. If you have medical equipment you would like to sell to Soma, send us a message here!

Banner

Questions about our Anesthesia Monitors and Agent Monitors?

Soma Tech Intl offers a wide range of Anesthesia Monitors and Agent Monitors. If you have any questions about any of our monitors or need a quick quote, call us and one of our knowledgeable sales representatives will help you.

Looking to sell your Anesthesia Monitors and Agent Monitors? Soma ensures your facility gets top dollar for your equipment and also gives the option for trade-in credit.

1-800-GET-SOMA
Contact Us