Welch Allyn PIC 50
24-Hour QuotesPricing up to 50% below the cost of new,
with service and warranty included. Download Specifications
Welch Allyn PIC 50 Defibrillator Features
The Welch Allyn PIC 50 is a defibrillator that offers monitoring features. The Welch Allyn PIC 50 offers Biphasic waveforms, 12 lead ECG, Pacing, oxygen levels, invasive and non-invasive blood pressure, end-tidal CO2, and patient temperature. The PIC50 is a portable semi-automatic defibrillator that can be used for both hospital and in-transit use. The Welch Allyn defibrillator was designed for easy use with a 6.5-inch color display screen, a built-in ECG printer, and a clearly defined button. The System comes with defibrillator paddles for adult patients.
- Portable lightweight design that weighs 10lbs
- Rugged design makes it ideal for both in and out-of-hospital use
- Easy-to-use system with custom configurations
- Communication optional with cellular transition, fax, and data card transfers
Welch Allyn PIC 50 Defibrillator Specifications
Dimensions
- Height: 5.4in (13.7 cm)
- Width:12.6 in (32 cm)
- Length: 13.2 in (33.5 cm)
- Weight: 13.2 lb (6.0 kg) (with battery)
Defibrillator
- Waveform: Biphasic: Low-current, impedance-compensated, optimized terminating current, truncated exponential biphasic
- External Select: External: 2, 5, 7, 10, 20, 30, 50, 70, 100, 150, 200, 300, 360 JM
- Charge Time: < 10 seconds @ 360 J (typical)
- Charge indicator: : Audible and graphic
- Output: Adult paddles, internal paddles, pediatrics adapter, and multipurpose hands-free adapter available.
- Synchronizer: Delivers energy within 60 msec
- Disarm: Front panel Switch
Monitor/ Display
- Input: 12-lead PIC: 12-lead patient cable, paddles, or multipurpose hands-free adapter
- Size: 6.4″, (16.3 cm) diagonal, non-fade
- Type: Color active matrix TFT display
- Display Resolution: 640 x 480 pixels
- Sweep Speed: 25 mm/sec
- Lead Selections: Paddles (Pads), I, II, III, AVR, AVL, AVF, V</li.
- Frequency Response: (User-selectable)
- 2 to 20 Hz Limited mode
- 0.67 to 40 Hz Monitor mode
- 0.25 to 40 Hz Filtered Diagnostic mode
- 0.05 to 150 Hz Diagnostic mode
- Common Mode Rejection: 90 dB (Complies with AAMI EC13-1992 section 3.2.9.10)
- Heart Rate Meter: 20 to 300 BPM
- Heart Rate Alarms: User-selectable Size: 0.125, 0.25, 0.5, 1, 2, 4 cm/mV and auto-sizing
- ECG Output: 1 V/mV
Recorder
- Type: High-resolution thermal array
- Annotation: Time, date, ECG lead, ECG gain, heart rate, defibrillation and pacing parameters, and treatment summary ACLS events
- Paper Width: 50 mm
- Paper Speed: 25 mm/sec, 50 mm/sec
- Delay: 6 seconds
- Frequency Response: Automatically set to monitor’s frequency response
- Treatment Summary: 7 switches to record key ACLS events (IV, INTUB, EPI, LIDO, ATROP, etc.). Automatically logs into memory the type of event, time, and ECG sample
- Tx Summary Log: 60 ECG events or 4,000 non-ECG events
- Record Modes: Manual and automatic
- Voice MemoTM (optional): Quickly and easily records the operator’s voice into the internal memory
- Record Modes: Manual & automatic (user configurable)
Battery
- High-Capacity Type: NiMH 12 V Welch Allyn SuperPac
- Low-Battery Indicator: Flashing low-battery icon on display
- Multiple Paired Contacts: Ensure quick, error-free insertion and backup reliability
- Recharge Rate*: 80% in 7.5 hours, 100% in 9.5 hours
12 Lead
- Acquired 12-lead: I, II, III, AVR, AVL, AVF, V1- V6 acquired simultaneously
- Transmitting: Optional fax/modem; 10 seconds of ECG (12 leads)
- Printing: 3-second samples of 12 leads
- 12-lead Interpretation (optional): Provides interpretation statements and measurements. Also provides Welch Allyn’s exclusive on-screen display and review of interpretation results
Pulse Oximeter
- Measurement Range: 31 to 99%
- Heart Rate Range: 30 to 250 BPM ± 5% or 5 BPM (whichever is less)
- Accuracy: 81 to 99% = ± 2%, 70 to 80% = 3%, 0 to 69% unspecified
- Update Period: Every pulse after 4 valid pulses
- Messages: Check Probe, Searching, Signal OK, No Signal, Poor Signal, Alarms Enabled/Disabled (icon), Testing
- Alarm Limits: 60 lower limits, 70 upper limits to 99%.
- Probe: Reusable finger or multisite probe
Pacer (option)
- Type: External transcutaneous pacing. <?li>
- Pacer Rate: 30 to 180 BPM ± 5%
- Output Current: 30 to 180 mA ± 10% or 5 mA (whichever is greater)
- Modes: Demand and asynchronous
- Status Indicators: ECG lead fault, pace lead fault, pace marker on monitor and chart, start/stop LED
- Pulse Type: Rectangular, constant current
- Pulse Width: 20 ms
- Refractory Period: 250 ms
- Output Protection: 360 joules
IBP (option)
- 2 Channels: Systolic, Diastolic, MAP, and waveform displays
- Pressure Range: -30 to 300 mmHg
- Accuracy: 2%
- Transducer: 5µV/V/mmHg
- Offset Imbalance: ±125 mmHg, including transducer offset
CO2
- Mainstream CO2 : C02 and EtCO2 display
- Range: 0 to 76 mmHg
- Accuracy: + 4 mmHg (< 40 mmHg), + 10% (> 40 mmHg)
- Resolution: 1 mmHg
- Respiration Range: 3 – 60 BPM
NIBP (option)
- Technique: Noninvasive oscillometric method, referenced to auscultatory standard, using the 5th Korotkoff sound as the diastolic reference
- Operating Modes: Automatic and manual
- Initial Cuff Inflation: Adult and child: 154 mmHg, Infant: 125 mmHg
- Automatic Cycle Times: 1, 2, 3, 5, 10, 30-minute intervals
- Blood Pressure Range: Systolic: 30 to 245 mmHg, Diastolic: 10 to 210 mmHg
- Heart Rate Range: 30 to 200 BPM ± 10% or 5 BPM
- Blood Pressure Accuracy: +5 mmHg mean error, +8 mmHg standard deviation
- Blood Pressure Validation: Blood pressure measurements determined with this device are equivalent to those obtained by a trained observer using the cuff/stethoscope auscultation method within the limits prescribed by the American National Standards Institute
- Alarms: Artifact, check cuff, tighten cuff, cuff leak, motion
- Alarm Limits: Systolic: 30 to 250 mmHg Diastolic: 25 to 250 mmHg
Temperature (option with NIBP)
- Measurement Range: 32° to 122°F (0° to 50°C)
- Accuracy: 0.3°F (± 0.2°C)
- Resolution: 0.1°F (0. °C)
- Scale: Fahrenheit or Celsius
- Probe: YSI Series 400
- Alarm Limits: High 99-109 °F (37° to 43°C); low 85-98°F (29° to 36°C) alarm limits
AED (option)
- Configurable: Basic & Basic+ modes
- Operation: Continuous analysis of ECG advises shock on VFIB, shockable VTACH <?li>
- Energy Sequence: User-configurable
- Monophasic: 200/200/360 J or 200/300/360 J
- Biphasic: 150/200/300/360 J
- Factory Default:
- Monophasic: 200/300/360 J
- Biphasic: 150/200/300 J
- Prompts: Audible voice and visual text prompts