Natus NatalCare ST-LX
24-Hour QuotesPricing up to 50% below the cost of new,
with service and warranty included.
Natus NatalCare ST-LX Features
The Natus NatalCare ST-LX is an intensive care incubator used to maintain stable temperature and humidity for newborns. It provides a controlled and isolated environment for infants who need extended care in NICU or pediatric intensive care units. The NatalCare incubator includes a large LCD display for clear data readouts and supports operation for either single infants or twins. Safety and reliability are central to its design, with electronic control systems and multiple alarms to protect the patient.
- Temperature Control: Operates in two modes — Skin Mode (maintains baby skin temperature) and Air Mode (maintains ambient air temperature). Temperature limits can be adjusted up to 38°C (100.4°F) for skin and 39°C (102.2°F) for air.
- Access and Visibility: Equipped with four foldable 180° care doors, five oval hand ports, and a double-wall hood that maintains thermal stability while allowing quick access.
- Display: The built-in graphic LCD screen shows temperature readings, system settings, and module status for features such as humidity, oxygen, and the weighing scale.
- Alarm Systems: Includes both visual and audible alarms for temperature deviation, power failure, air flow interruption, and overheating.
- Tilting Function: Electronic mechanism adjusts the bassinet angle up to ±15° for positioning and patient care.
- Optional Modules: Can include servo-controlled oxygen (21–80%), servo-controlled humidity (40–95%), and an electronic weighing scale with an 8000 g capacity and ±5 g accuracy.
- Dual Temperature Probes: Supports two probes (T1 and T2) for use with twins or for monitoring different body points on one infant to assess temperature variation.
Natus NatalCare ST-LX Specifications
Dimensions
- Height: 53.1 in (135 cm)
- Width: 41.3 in (105 cm)
- Depth: 23.6 in (60 cm)
- Weight: 172 lbs (78 kg)
Physical Attributes
- Baby Compartment (Useful Area): 31.5 in W x 15.7 in H x 18.9 in D (80 x 40 x 48 cm)
- Mattress Area: 24 in W x 15.7 in D (61 x 40 cm)
- Bassinet Tilting: ±15° electronic tilt
Temperature Control & Performance
- Air Control Range: 68°F to 98.6°F (20°C to 37°C), override to 102.2°F (39°C)
- Skin Control Range: 93.2°F to 98.6°F (34°C to 37°C), override to 100.4°F (38°C)
- Temperature Accuracy: ±0.6°F (±0.3°C)
- Temperature Resolution: 0.1°F (0.1°C)
- Warm-up Time: Approximately 30 minutes
Power Supply
- Input Voltage: 120 V~ or 230 V~, 50/60 Hz
- Power Consumption: 12 A (120V~), 6 A (230V~)
- Maximum Load: 345 VA
Environmental Conditions
- Operating Temperature: 64.4°F to 86°F (18°C to 30°C)
- Operating Humidity: 50% ±5% (non-condensing)
- Storage Temperature: 40°F to 110°F (4°C to 43°C)
Refurbished Natus NatalCare ST-LX Incubator
Soma Tech Intl offers the Natus NatalCare ST-LX up to 50% below OEM prices with the same service and warranty as new. The incubator is not only technically refurbished but also cosmetically refurbished to make it work and look like new. When the refurbishing process starts on the NatalCare ST-LX, it is carefully inspected and tested by our own in-house biomedical engineers who are highly skilled and certified to work on neonatal equipment. If necessary, parts are replaced to ensure that all aspects of the incubator meet the original manufacturer’s specifications. This ensures that the unit operates just as it did when it left the manufacturer. Once the NatalCare ST-LX is functioning like new, it undergoes a specialized cosmetic restoration. The incubator is cleaned, minor scratches and dents are repaired, it’s repainted, and new decals are added if necessary. After this thorough refurbishment, the unit both functions and appears like new. Soma Tech Intl is ISO 13485 certified, ensuring top-quality standards in every piece of medical equipment sold. Before the Natus NatalCare ST-LX is labeled patient-ready and prepared for shipment, it goes through a final quality control check to confirm all aspects are working as they should. If you are interested in a refurbished incubator, contact Soma at soma@somatechnology.com or call us at 1-800-438-7662.
Soma Tech Intl actively seeks to purchase incubators. If you or your facility are looking to sell your Natus NatalCare ST-LX, contact Soma Tech Intl. Soma’s experienced purchasing team will guide you through the process to ensure your medical facility receives the best value for your equipment. Soma is fully HIPAA-compliant and ensures your equipment arrives in the same condition it left your facility. Soma also offers trade-in credits for medical equipment. If you have equipment to sell, send us a message here.