Axia V1050T Touch Screen
24-Hour QuotesPricing up to 50% below the cost of new,
with service and warranty included. Download Specifications
Axia V1050T Touch ScreenFeatures
The Axia V1050T is a patient monitor that can adapt to any situation. The high-resolution, 10.5-inch touch screen makes it easy to see and quickly modify the parameters needed for the patient’s condition. The Axia V1050T offers standard measurements such as; non-invasive blood pressure, ECG, motion-tolerant SpO2, temperature, and respiration rate. End-tidal CO2, anesthesia agent measurements, Cardiac output, and invasive blood pressure can be added by attaching a plugin module to the monitor. The patient monitor can hold up to 72 hours of detailed patient data. The Axia Monitor is only 7 pounds making it easy to move the monitor with the patient from the bedside monitor to the operating room without disconnecting.
- High resolution 10.5 inch touch-screen display
- Auto setting of alarm limits
- Color-coded alarms
- Graphical and tabular trends (72 hours)
- Patient data entry
- Battery backup (removable batteries)
- Networking capability (wireless and non-wireless)
- The color of the waveforms can be changed
- Applications: Neonatal, pediatric, and adult patients
- Can be upgraded to add CO2
Axia V1050T Tuch Screen Specifications
Dimensions
- Height: 11 in (27.94 cm)
- Width: 12 in (30.48 cm)
- Depth: 5 in (12.7 cm)
- Weight: 7lb (3.175 kg)
Display
- 10.5 inch color touchscreen
Trace
- 8 waveforms
Indicator
- Alarm indicator
- Power indicator
- QRS beep and alarm sound
Trend Time
- 1 – 72 hour
- Recorder: Built-in, thermal array, 3 channels
- Record width: 48mm
- Recorder paper: 50mm
- Record speed: 25mm/s, 50mm/s
Networking
- Industry standard 802.11b/g wireless network
Power
- Source: External AC power or internal battery
- AC Power: 100 ~ 240VAC, 50/60Hz, 150VA
- Battery: Built-in & rechargeable lithium-ion
- Operating Time: 3+ hours
Environmental Specifications
- Input: 5-lead ECG cable and standard AAMI line for connection
- Lead Choice: I, II, III, aVR, aVF, aVL, V, V1-V6, TEST
- Gain Choice : x0.5, x1, x2, x4
- Frequency Characteristic: 0.05 ~ 35 HZ (+3dB)
- ECG Waveforms: 7 channels
- Penetration Voltage: 4000VAC 50/60Hz
- Sweep Speed: 12.5, 25, 50, and 100 mm/sec (left to right or right to left)
- HR Display Range: 30 ~ 300bpm
- Accuracy: ±1bpm or ±1%, whichever is greater
- Alarm Limit Range Setting: upper limit 100 ~ 200bpm, lower limit 30 ~ 100bpm
RESP
- Measure Method: RA-LL impedance
- Range: 0 ~ 120 rpm
- Accuracy: ±3 rpm
- Alarm Limit Setting: upper limit 6 ~ 120 rpm, lower limit 3 ~ 120 rpm
- Sweep Speed: 12.5, 25, 50, and 100 mm/sec (left to right or right to left)
Sp02
- ASpO2: Anti-motion SpO2
- SpO2% Range: • SpO2 Accuracy: 0-100%
- Pulse Rate Range: ±2% (70 ~ 100%, non-motion), ±3% (70 ~ 100%, motion)
- Pulse Rate Accuracy: ±2 bpm (non-motion, ±3 bpm (motion)
- Alarm Limit Setting: upper limit 70 ~ 100%, lower limit 70 ~ 100%
- SpO2 Probe: Red light LED wavelength 660nm±5nm, Infrared light LED wavelength 940nm±10nm
ECG
-
- Input: 5-lead ECG cable and standard AAMI line for connection
Lead Choice: I, II, III, aVR, aVF, aVL, V, V1-V6, TEST
- Gain Choice : x0.5, x1, x2, x4
- Frequency Characteristic: 0.05 ~ 35 HZ (+3dB)
- ECG Waveforms: 7 channels
- Penetration Voltage: 4000VAC 50/60Hz
- Sweep Speed: 12.5, 25, 50, and 100 mm/sec (left to right or right to left)
- HR Display Range: 30 ~ 300bpm
- Accuracy: ±1bpm or ±1%, whichever is greater
- Alarm Limit Range Setting: upper limit 100 ~ 200bpm, the lower limit 30 ~ 100bpm
NIBP
- Measuring Technology: automatic oscillating measurement
- Cuff Inflating <30s (0 ~ 300 mmHg, standard adult cuff)
- Measuring Period: AVE<40s
- Mode: Manual, Auto
- Measuring Interval in AUTO Mode: 2 min ~ 4 hrs
- Pulse Rate Range: 30 ~ 250 (bpm)<//li>
- Adult/Pediatric Mode: SYS: 40 ~ 250 (mmHg) DIA :15 ~ 200 (mmHg)
- Neonatal Mode: SYS: 40 ~ 135 (mmHg) DIA : 15 ~ 100 (mmHg)
- Maximum Mean error: ±5mmHg
- Maximum Standard deviation: 8mmHg
- Resolution: 1mmHg
- Overpressure Protection: Adult Mode: 300 (mmHg)
- Neonatal Mode: 160 (mmHg)
- Alarm Limit Setting: SYS: 50 ~ 240 mmHg
- DIA: 15 ~ 180 mmHg