Mindray Passport 17m
24-Hour QuotesPricing up to 50% below the cost of new,
with service and warranty included. Download Specifications
Mindray Passport 17m Features
The Mindray Passport 17m is a patient monitor that can be used on adult, pediatric, and neonatal patients. This Passport monitor is intended for monitoring and displaying ECG (3, 5, and 12-lead), Arrhythmia Detection, ST-segment Analysis, QT Analysis, Heart Rate, Respiration, Temperature, SpO2, Pulse Rate, NIBP, IBP, PAWP, Cardiac Output, Continuous Cardiac Output, SvO2, CO2, O2, Anesthetic Gas, ICG, BIS, RM, and interpretation of resting 12-lead ECG. Under the maximum configuration, this Mindray monitor has one 2-slot module rack, one 3-slow module rack, and one satellite module rack. Different modules can be equipped to fit you or our facility’s needs. This multiparameter monitor also has a 17-inch high-resolution TFT LCD display with a resolution of 1280×1024 pixels.
- Supports 12 different modules that include SpO2, MPM, IBP, C.O., CCO/ ScO2, CO2, AG, BIS, RM, ScvO2, T1, and BeneLink.
- Supports the Mindray T1 as a multi-measurement module. When disconnected the T1 can be used as a stand-alone monitor.
- 4 different operating modes include Monitoring Mode, Night Mode, Privacy mode, and Standby Mode.
- 5 default configurations include General, OR, ICU, NICU, and CCU.
Mindray Passport 17m Specifications
Dimensions
- Height: 15.7 in (40 cm)
- Width: 14.5 in (37 cm)
- Depth: 7.6 in (19.3 cm)
- Weight: 26.5 lbs (12 kg) (Without modules, batteries, accessories, or recorder)
Display
- Type: Color TFT LCD
- Screen Size (Diagonal): 17”
- Resolution: 1280×1024
Recorder
- Method: Thermal dot array
- Horizontal Resolution: 16 dots/mm (25 mm/s paper speed)
- Vertical Resolution: 8 dots/mm
- Paper Width: 50 mm
- Paper Length: 20 m
- Paper Speed: 25 mm/s, 50 mm/s
- Number of Waveform Channels: Maximum 3
Battery
- Number of Batteries: 2
- Battery Type: Rechargeable Lithium-Ion
- Voltage: 11.1 VDC
- Capacity: 4500 mAh
- Run Time: ~120 minutes
- Charge Time: Less than 6h
Storage
- Trends: 120 hours, at 1 min resolution; Mid-length trends: 4 hours, at 5 s resolution; Minitrends: 1 hour, at 1 s resolution
- Parameter Alarms: 100 physiological alarms and manual events and related parameter waveforms.
- OxyCRG Events: 100 OxyCRG events
- Arrh. Events: 100 arrhythmia events and related waveforms and parameters.
- NIBP Measurements: 1000 sets
- Full-disclosure Waveforms: 48 hours at maximum. The specific storage time depends on the waveforms stored and the number of stored waveforms.
Compatible Modules
- Supported Modules: SpO2, MPM, IBP, C.O., CCO/ScO2, CO2, AG, BIS, RM, ScvO2, T1, BeneLink
MPM Module
- ECG
- Leads: 3, 5, and 12-Lead
- Sampling Rate: 500 samples/s (A/D); 500 samples/s (ECG algorithm)
- Accuracy: 2.44µV/LSB
- Heart Rate: Yes
- ST Segment Analysis: Yes
- Respiration
- Measurement Range: Adult: 0 to 120 rpm ; Pediatric, neonate: 0 to 150 rpm
- Resolution: 1 rpm
- Accuracy: 7 to 150 rpm (±2 rpm or ±2%, whichever is greater)
- SpO2
- SpO2 High: (low limit + 2) to 100
- SpO2 Low: Masimo: Desat to (high limit – 2); Nellcor: Desat or 20 (whichever is greater) to (high limit – 2)
- Desat: 0 to (high limit – 2)
- Temperature
- Measurement Range: 0 to 50 °C (32 to 122°F)
- Resolution: 0.1 °C
- Accuracy: ±0.1 °C or ±0.2 °F (without probe)
- NIBP
- Mode of Operation: Manual, Auto, and STAT
- Max Measurement Time: Adult/Pediatric: 180 s; Neonate: 90 s
- Heart Rate Range: 40 to 240 bpm
- Accuracy: Max mean error: ±5 mmHg; Max standard deviation: 8 mmHg
- Resolution: 1mmHg
- IBP
- Measurement Range: -50 to 300 mmHg
- Resolution: 1 mmHg
- Accuracy: ±2% or ±1 mmHg, (whichever is greater (without sensor))
- PPV Measurement Range: 0% ~ 50%
SpO2 Module
- Measurement Range: 1 to 100%
- Resolution: 1%
- Response time: =20s
- Refreshing Rate: = 2 s
- SpO2 Averaging Time: 2-4 s, 4-6 s, 8 s, 10 s, 12 s, 14 s, 16 s
IBP Module
- Measurement Range: -50 to 300 mmHg
- Resolution: 1 mmHg
- Accuracy: ±2% or ±1 mmHg, (whichever is greater (without sensor))
- PPV Measurement Range: 0% ~ 50%
C.O. Module
- Measurement Method: Thermodilution method
- C.O.: Measurement Range: 0.1 to 20 L/min; Resolution: 0.1 L/min; Accuracy: ±5% or ±0.1 L /min, whichever is greater
- TB: Measurement Range: 23 to 43 °C; Resolution: 0.1 °C; Accuracy: ±0.1 °C (without sensor)
- TI: Measurement Range: 0 to 27 °C; Resolution: 0.1 °C; Accuracy: ±0.1 °C (without sensor)
CCO Module
- Operating Mode: Interfaces with Edwards Vigilance II or Vigileo monitor
- Measured Parameter: Consistent with CCO-related parameters output by Vigilance II or Vigileo monitor
- CCO: 1 to 20 L/min; Resolution: 0.1
- CCI: 0 to 20 L/min/m2; Resolution: 0.1
- CO: 1 to 20 L/min; Resolution: 0.1
- CI: 0 to 20 L/min/m2; Resolution: 0.1
CO2 Module
- Measurement Mode: Sidestream, micro stream
- Technique: Infrared absorption
- CO2 Measurement Range: 0 to 99 mmHg
- Resolution: 1 mmHg
AG Module
- Technique: Infrared absorption
- Measurement Range: CO2: 0 to 30%; O2: 0 to 100%; N2O: 0 to 100%; Des: 0 to 30%; Sev: 0 to 30%; Enf: 0 to 30%; Iso: 0 to 30%; Hal: 0 to 30%; awRR: 2 to 100 rpm
- Resolution: CO2: 1 mmHg; awRR: 1 rpm
BIS Module
- Technique: Bispectral index
- Measured Parameters: EEG; BIS, BIS L, BIS R: 0 to 100
RM Module
- Technique: Flow sensor
- Frequency Response: =30 Hz
- Dead Space: =11 ml
- Flow Measurement Range: Adult/pediatric: ± (2 to 120) L/min; Infant: ± (0.5 to 30) L/min
- Paw Measurement Range: -20 to 120 cmH2O
- MVe/MVi Measurement Range: Adult/Pediatric: 2 to 60 L/min; Infant: 0.5 to 15 L/min
- TVe/TVi Measurement Range: Adult/Pediatric: 100 to 1500 ml; Infant: 20 to 500 ml
- RR (RM) Measurement Range: 4 to 120 rpm
ScvCO2 Module
- Measurement Range: 0 to 99%
- Accuracy: 50% to 80%: ±3%
BeneLink Module
- Used for transmitting information from an external source to the monitor. See the operating manual for compatible anesthesia machines, ventilators, neuromuscular transmission monitors, and transcutaneous monitors.
T1
- The T1 can be connected to the Passport 17m as a multi-measurement module. It can be used to monitor temperature, IBP, NIBP, ECG, and SpO2. When disconnected from the 17m The T1 can continue to be used as a stand-alone patient monitor that runs on battery power.