Mindray V12
24-Hour QuotesPricing up to 50% below the cost of new,
with service and warranty included. Download Specifications
Mindray V12 Features
The Mindray V12 monitoring platform is a modular patient monitoring system. The system architecture allows users to customize, by removal or addition of modules, monitored parameters based on patients monitoring needs or acuity levels. The V Series monitoring platform maximizes the amount of viewable data through the use of a portrait display orientation.
- 12.1 in color touchscreen display with up to 8 waveforms.
- 3, 5,6, or 12 lead ECG.
- Ability to integrate with Panorama Central Stations and Nurse Call Systems.
- IV drug calculations and hemodynamic calculations.
- Modern User-interface.
- Interchangeable system elements.
- Consistent performance and easy maintenance.
Mindray V12 Specifications
Dimensions
- Height: 13.7 in (34.8 cm)
- Width: 9.4 in (23.9 cm)
- Depth: 7.5 in (19.1 cm)
- Weight: 8.9 lbs (4.03 kg) (Without batteries)
Display
- Type: TFT Display
- Size: 12.1 in (30.7 cm)
- Aspect Ratio: 3:4
- Resolution: 1024 x 768 pixels
ECG (3,5,6 Lead)
- Range: Neonatal BPM: 30 to 350; Pediatric and Adult BPM: 30 to 300
- Resolution: 1 BPM
- Accuracy: ±3 BPM or ±3% from 30 to 250 BPM, whichever is greater and ±5% in the 251 to 350 BPM range
ECG (12 Lead)
- Range: Neonatal, Pediatric, and Adult BPM: 30 to 300
- Resolution: 1 BPM
- Accuracy: ±3 BPM or ±3% from 30 to 250 BPM, whichever is greater and ±5% in the 251 to 350 BPM range
NIBP Systolic Pressure
- Accuracy: Mean error ±5 mmHg
- Standard Deviation: Less than 8 mmHg
- Measurement Range: Adult Mode: 55 to 235 mmHg; Pediatric Mode: 55 to 160 mmHg; Neonate Mode: 45 to 120 mmHg
- Resolution: 1 mmHg
NIBP Diastolic Pressure
- Accuracy: Mean error ±5 mmHg
- Standard Deviation: Less than 8 mmHg
- Measurement Range: Hg Adult Mode: 30 to 200 mmHg; Pediatric Mode: 30 to 150 mmHg; Neonate Mode: 20 to 100 mmHg
- Resolution: 1 mmHg
NIBP Heart Rate
- Accuracy: Greater of ± 3 BPM or ± 3%
- Resolution: 1 BPM
- Measurement Range: Adult Mode:35 to 245 BPM; Pediatric Mode:35 to 245 BPM; Neonate Mode:70 to 245 BPM
IBP
- Accuracy: ± 2mmHg or 2% of the signal value whichever is greater (excluding transducer error).
- Resolution: 1 mmHg
IBP Heart Rate
- Range: Adult Mode:30 to 300 BPM; Pediatric Mode:30 to 300 BPM; Neonate Mode: 30 to 350 BPM
- Resolution: 1 BPM
- Accuracy: ± 3 BPM or ± 3% at 30 to 250 BPM ± 5 BPM or ± 5% from 251 to 350 BPM
Temperature
- Range: 59°F to 113°F (15°C to 45°C)
- Resolution: 0.1°F (0.1°C)
- Accuracy: ± 0.2°F (± 0.1°C)
SpO2
- Range: 70% to 100%
- Resolution: 1%
- Update Rate: 2 seconds
- Nellcor SpO2 Heart Rate: Range: 20 to 249 BPM; Accuracy ±3 BPM
- Massimo SpO2 Heart Rate: Range: 26 to 239 BPM; Accuracy ±3 BPM
Thermomodulation Cardiac Output (CO)
- Range: 0.2 to 20.0 liters/minute
- Range for Hospira: 1.0 to 20.0 liters/minute
- Range for Edwards Life Science: 1.0 to 20.0 liters/minute
- Resolution: 0.1 liters/minute
- Accuracy: 5% or 0.2 liters/minute, whichever is greater
- Repeatability: + 2% or 0.2 liters/minute, whichever is greater as measured by electronically generated flow curves
CO2
- Performance: 0-99 mmHg
- Respiration Rate Range: 0 to 150 RPM
- Flow Rate: 50 ml/min -7.5 + 15 ml/min, flow measured by volume
- Respiration Rate Accuracy: 0 to 70 RPM ± 1 RPM; 71 to 120 RPM ± 2 RPM; 121 to 150 RPM ± 3 RPM