Medtronic 53401 Single Chamber Features
The Medtronic 53401 Single Chamber External Temporary Pacemaker is designed for clinical environments requiring short-term atrial or ventricular pacing. Its intuitive interface and constant-current output ensure reliable therapy delivery, adapting to changes in lead impedance. With modes for both demand (synchronous) and asynchronous pacing, it supports therapeutic, prophylactic, and diagnostic applications. The device is MR Unsafe and must be used with continuous patient monitoring.
- Multi-Mode Pacing: Supports AAI, AOO, VVI, and VOO modes for flexible therapy.
- Wide Rate Range: Basic pacing (30–200 ppm) and rapid atrial pacing (80–800 ppm).
- Adjustable Output: 0.1–25 mA amplitude with a fixed 1.5 ms pulse width.
- Enhanced Sensitivity: 0.4–20 mV sensing to detect intrinsic rhythms.
- Long Battery Life: Up to 19 days with two AA alkaline batteries (IEC LR6).
- Ergonomic Design: Lightweight (499 g) and compact for one-handed operation.
- Safety Features: 200 ms blanking post-pace, 120 ms post-sense to prevent oversensing.
Medtronic 53401 Single Chamber Specifications
Dimensions
- Height: 7.98 in (20.27 cm)
- Width: 2.63 in (6.68 cm)
- Depth: 1.63 in (4.14 cm)
- Weight: 17.6 oz (499 g)
Power
- Battery Type: 2 × AA alkaline (LR6, e.g., Duracell MN1500).
- Battery Life: Up to 19 days under typical use (Medtronic study, 2016).
Operational
- Pacing Modes: AAI, AOO, VVI, VOO.
- Rate Ranges:
- Basic: 30–200 ppm.
- Rapid Atrial: 80–800 ppm.
- Output: 0.1–25 mA (constant current).
- Pulse Width: Fixed at 1.5 ms.
- Sensitivity: 0.4–20 mV.
- Blanking Periods:
- 200 ms ±5/-30 ms (post-pace).
- 120 ms ±2/-30 ms (post-sense).
- Electrode Compatibility: Unipolar or bipolar leads.
Environmental
- Service Life: 7 years.
- MR Status: MR Unsafe.
Refurbished 53401 Medtronic External Temporary Pacemaker
Soma Tech Intl offers the Medtronic 53401 Single Chamber External Temporary Pacemaker up to 50% below OEM prices with identical service and warranty. The 53401 undergoes rigorous technical and cosmetic refurbishment by certified biomedical engineers. Each unit is inspected, tested, and restored to meet original manufacturer specifications, including battery compartment integrity and output calibration. Cosmetic repairs address scratches, and the device is sanitized to clinical standards. Soma Tech Intl’s ISO 13485 certification guarantees quality, with a final QC check confirming patient-ready performance. Contact us at soma@somatechnology.com or 1-800-438-7662.