Criticare Poet IQ 8500H
24-Hour QuotesPricing up to 50% below the cost of new,
with service and warranty included. Download Specifications
Criticare Poet IQ 8500H Features
The Criticare Poet IQ 8500H agent gas analyzer measures real-time concentrations of anesthetic agent gases. The device measures gases using a sidestream method. The primary module measures concentrations of CO2, N2O, and halogenated anesthetic agents. The Criticare Poet IQ 8500H can also measure oxygen concentrations using a galvanic cell. The gas sample enters the monitor from a sampling tube into a water trap, which removes water vapor and particulate matter from the gas sample.
- Integrated CO2/agent detector.
- Measures carbon dioxide, nitrous oxide, and five halogenated anesthetic agents.
- Uses proprietary High IQ technology to identify and quantify agent gases.
- No moving parts.
- Reduced size.
- Reliable.
Criticare Poet IQ 8500H Specifications
Dimensions
- Height: 4.2” (10.7 cm)
- Width: 13.75” (34.9 cm)
- Depth: 10.75” (27.3 cm)
- Weight: 7.5 lb (3.4 kg)
Pneumatics
- Flow rate: 100, 150, 200 ml/min, User Selectable
- Occlusion Clearing: Automatic
- Filters: WaterChek 2+
- Sample Lines: Cat. No. 625N, 8 foot
- Pneumatic Sound Pressure: 45 dBa maximum @ 1 meter
Communications
- Communication: Async Serial (RX/TX); CANBUS
- IBench Data Port: DB-9 connector
- Charger Port: 12.0VDC nominal, 1.0 Amp nominal
Capnometry (CO2)
- Method: Sidestream; non-dispersive infrared
- Range: 0-99 mmHg, 0 to 12.5%, 0 to 12.5 kPa, 0 to 99 Torr
- Resolution: 1 mmHg, 0.1%, 0.1 kPa, 1 Torr
- Accuracy: ±0.2% abs. or 4% of reading for breath rates up to 60 breaths/minute
- Flow Rate: 100, 150, 200 ml/min, user selectable
- Flow Tolerance: ±10%
- Rise Time: (10-90%) 350 milliseconds @ 150 ml/min
- Response Time: 2.25 seconds
- Time from Cold Stat: 1 minute to first waveforms; <20 minutes to full accuracy
- Calibration: Auto-calibrating, Manual Calibration
- Units: mmHg; Volume Percent; kPa; Torr
- Display: Inspired CO2, Expired CO2 (End-Tidal) Numerical values, capnograph, and breath by breath EtCO2 bar graph.
CO2 Respiration
- Source: Capnogram
- Range: 1 to 100 breaths/minute
- Resolution: 1 breath/minute
- Accuracy: ± 2 breaths/minute or 2% of reading
Nitrous Oxide (N2O)
- Method: Sidestream; non-dispersive infrared
- Range: 0 to 99 volume percent
- Resolution: 1%
- Accuracy: ± (1.5% abs. + 4% of reading) for breath rates up to 60 breaths/minute
- Identification Threshold: 5% (for single and mixed agents)
- Rise Time: (10-90%) 400 milliseconds
- Response Time: 2.5 seconds
- Calibration: Auto-calibrating, Manual Calibration
- Units: Percent
- Display: Numerical Inspired N2O, Expired N2O; N2O waveform
Oxygen Monitoring (O2)
- Units: Percent
- Display: Inspired O2, Expired O2, Numerical values, waveform
- Method: Oxidation-reduction galvanic cell
- Range: 0-100%
- Resolution: 1%
- Accuracy: ± 3 vol. % (0 – 90%) ± 4 vol. % (91- 100%) for breath rates up to 60 breaths/minute
- Rise Time: (0-90%) 600 milliseconds
- Response Time: 1.5 seconds
Halogenated Agents
- Method: Sidestream; non-dispersive infrared
- Units: Volume Percent
- Resolution: 0.1 Volume Percent
- Range
- Halothane; 0 to 10.0 vol. %
- Isoflurane; 0 to 10.0 vol. %
- Enflurane; 0 to 10.0 vol. %
- Desflurane; 0 to 20.0 vol. %
- Sevoflurane; 0 to 10.0 vol. %
- Accuracy: ± (0.1% abs. + 4% of reading) for breath rates up to 60 breaths/minute
- Identification Threshold
- Halothane; 0.2 vol. %
- Isoflurane; 0.3 vol. %
- Enflurane; 0.3 vol. %
- Desflurane; 0.3 vol. %
- Sevoflurane; 0.3 vol. %
- Mixed Gas Threshold: 0.2 vol. % + 10% of total concentration
Refurbished Criticare Poet IQ 8500H Agent Monitor
Soma Tech Intl offers Criticare Poet IQ 8500H Agent Monitor up to 50% below OEM prices with the same service and warranty as new. The Criticare Poet IQ 8500H is not only technically refurbished but also cosmetically refurbished to make it work and look like new. When the refurbishing process starts on the agent monitor, it is carefully inspected and tested by our own in-house biomedical engineers who are highly skilled and certified to work on surgical tables. If necessary, parts are replaced to make sure that all aspects of the Criticare Poet IQ 8500H are functioning properly. Once everything is in working order, the unit is calibrated back to the original engineering manufacturer’s specifications. This ensures that the unit is working the same way that it originally left the manufacturer. After the Criticare Poet IQ 8500H agent monitor is working like new it undergoes a special cosmetic restoration process. The Criticare Poet IQ 8500H is cleaned, minor scratches and dents are repaired, it’s painted, and new decals are replaced if necessary. After this strenuous refurbishing process, the Unit functions and looks like new. Soma Tech Intl is ISO 13485 certified and ensures that the best quality is given to all capital medical equipment that they sell. Before the Criticare Poet IQ 8500H is labeled patient-ready and packed up for shipment, it goes through one last quality control test that makes sure all aspects are again working as they should. If you are looking to buy a refurbished Criticare Poet IQ 8500H agent monitor contact soma at [email protected] or call us at 1-800-GET-SOMA.
Soma Tech Intl also purchases used and pre-owned Agent Monitor. If you or your facility wants to sell your Criticare Poet IQ 8500H, Soma Tech Intl has an experienced purchasing department that makes the process headache and hassle-free. When selling your agent monitor to Soma, there is no need for a middle man, it is a direct transaction to Soma which ensures that you get top dollar for your medical equipment. Soma Tech Intl not only buys agent monitors but a wide variety of different medical equipment as well if your medical facility is looking to free up space. If you have medical equipment you would like to sell to Soma, send us a message here!