Mindray Datascope Gas Module II

24-Hour Quotes

Pricing up to 50% below the cost of new,
with service and warranty included.
Download Specifications

Mindray Datascope Gas Module II Features

The Mindray Datascope Gas Module II is a companion to several patient monitors. The Gas Module II, commonly called the Datascope GM2, is capable of automatically identifying and measuring five anesthetic agents (Desflurane, Enflurane, Sevoflurane, Halothane, and Isoflurane, as well as N20, CO2, and O2. This unit monitors all gases via sidestream sampling.

  • 200 mL/min sample flow rate.
  • Uses a non-dispersive infrared analyzer to measure the absorption of the gas sample at seven infrared wavelengths.
  • 2.5-second sampling delay
  • Water trap that removes water and impurities from the patient sample.
  • Analyzes patient samples at a fixed rate.

Mindray Datascope Gas Module II Specifications

Dimensions

  • Height: 4.2” (10.6 cm)
  • Width: 12.5” (31.7 cm)
  • Depth: 9.6” (24.3 cm)
  • Weight: 10 lb (4.5 kg)

Performance

  • Sampling Rate: 200 ± 20 ml/min (with sampling line = 6 meters, under normal conditions)
  • Sampling Delay: 2.5 seconds (with a 3-meter sampling line)
  • Total System Response Time: 2.9 seconds (with a 3-meter sampling line, including sampling delay and rise time)
  • Display Update Rate: Breath-by-Breath
  • Compensation: Automatic for pressure, CO2-N2O and CO2-O2 collision broadening the effect
  • Warm-up Time: Maximum 2 minutes to operation with CO2, O2, and N2O; 5 minutes to the operation of anesthetic agents; 30 minutes for full accuracy specifications
  • Autozeroing Interval: At startup and at 2, 4, 10, 15, 30, 45, and 60 minutes of operation. Every 60 minutes thereafter

Pneumatic

  • Technology: Side-stream gas sampling
  • Pneumatic Modes: Room air reference measurement: Automatic; Sampling system purge: Automatic
  • Pump: Flow-controlled dual membrane
  • Gas sampling rate: with DRYLINE™ Water Trap, Adult/Ped: 200 ml/min; with DRYLINE™ Water Trap, Neonate: 120 ml/min
  • Occlusion Alarm: Actual flow < 40 ml/min
  • Room Air Reference Measurement: Automatic when gas measurement bench temperature change is > 1°C or time since the last ref. measurement is > 4 h
  • Reference Measurement Interval: ISO Accuracy Mode > 30 s Full Accuracy Mode > 4h
  • Reference Measurement Duration: Typical 5 s, Max 9 s
  • Purge Cycle: Automatic when occlusion detected

 