Drager Fabius OS Anesthesia Machine

February 7, 2017
Drager Fabius OS Anesthesia Machine

Dräger Fabius OS Features

  • Familiar operation and layout ensures ease of use and a short learning curve.
  • RS 232 enables communication with automated record keeping systems for enhanced patient throughput.
  • Convenient compact breathing system (COSY).
  • Ventilates any patient – even as your needs change to accommodate sicker patients with more complex procedures.
  • Consumes no drive gas, allowing dramatically increased ventilation time and reduced cost.

Dräger Fabius OS Specifications

Weight:

  • 296 lbs. (134.2 kg) (base unit without vaporizers or cylinders).

Dimensions:

  • 40.7 x 52 x 33 ″ (103.5 x 132 x 84 cm) (W X H X D) (with Cosy and   3-Vaporizer Mount).

Power Supply:

  • 100 – 240 VAC, 50/60 Hz, 2.3 A max. (non-configurable).

Operation Time:

  • Up to 120 minutes, minimum 45 minutes. (With fully charged batteries.)

Ventilator E-vent:

  • Electronically controlled, electrically driven.

Operating Modes Standard:

  • Volume Controlled Ventilation, Manual Ventilation, Spontaneous Breathing.

Operating Modes Options:

  • Pressure Controlled Ventilation, Pressure Support.

Breathing frequency:

  • 4 to 60 1/min.

Max. Minute volume (MV):

  • 0 to 99.9 L/min.

Positive end-expiratory pressure:

  • 0 – 20 cmH2O (PEEP).

Inspiration / Expiration ratio:

  • 4 : 1 to 1 : 4 (TI:TE).

Pressure Limiting:

  • 15 – 70 cmH2O (PMAX).

Tidal Volume (VT):

  • 20 – 1400 mL in Volume Control.

Inspiratory pause (TIP:TI):

  • 0 – 50 %.

Inspiratory pressure (PINSP):

  • PEEP + 5 to 65 cmH2O.

Inspiratory flow (InspFlow) 1:

  • 0 – 75 L/min in Volume and Pressure Control.
  • 10 – 85 L/min in Pressure Support.

Pressure Support Level (Δ PPS):

  • PEEP + 3 to 20 cmH2O.

Min. Frequency for apnea-ventilation:

  • 3 – 20 1/min and “ OFF ” (Freq. Min).

Trigger:

  • 2 – 15 L/min.

Integrated safety functions:

  • Sensitive Oxygen Ratio Controller (S-ORC) guarantees a minimum O2 concentration of 23% in an O2/N2O mixture.
  • N2O cut-off if O2 fresh gas valve is closed or if O2 flow is less than 0.2 L/min.
  • Audible and visual (flashing red LED) indication in case O2 pressure drops below 20 psi (1.4 bar) ± 4 psi (0.3 bar).
  • In case of electricity and battery failure, manual ventilation, gas delivery and agent delivery are possible.
  • Positive pressure relief valve opens at 75 ± 5 cmH2O.
  • Negative pressure relief valve opens at – 7.5 to – 9 cmH2O.

Range of fresh gas flow indicators:

  • 0.00 to 12.0 L/min.

Total fresh gas flow meter:

  • 0 to 10 L/min, calibrated with a mixture of 50 % O2 and 50 % N20 mixture.

O2 flush:

  • At 55 psi (3.8 kPa x 100): max. 50 L/min.
  • At 50 psi (3.4 kPa x 100): max. 35 L/min.

Vaporizer mount:

  • Auto Exclusion Drä ger mount.

Control screen:

  • 6.5” (16.5cm) black/amber.

Monitoring:

  • Continuous monitoring of inspiratory O2 concentration, breathing frequency, tidal volume, minute volume, mean or plateau pressure, peak airway pressure as well as PEEP.
  • In addition, all fresh gas flow information is displayed as virtual flow tubes.

Serial interface:

  • 1 x RS 232 (Standard).

Protocols:

  • Vitalink and Medibus.

Data available for export:

  • All fresh gas flow, ventilation and O2 data, flow and pressure real-time waveform.

Volume of CO2 absorber:

  • 1.5 Liter, Option: Dräger Medical’s prefilled CLIC absorber (1.2 l).

Gas supply:

  • O2, N2O & Air.

Cylinder yokes:

  • O2, N2O, Air, pin index yokes.

Additional accessories:

  • Gas scavenging, patient suction, power outlet strip, additional O2 flow tube.

Volume of entire compact breathing system:

  • 1.7 Liter + bag.

More:

Dräger Fabius GS