November 22, 2016GE OEC 9900 Elite Features:
- Precision imaging Dynamic Range Management (DRM) for uncompromised image quality.
- Touchscreen controls
- Proprietary “no mask” or Motion Tolerant Subtraction (MTS) technique produces vascular images not previously possible on a mobile platform. Capabe to perform a complete extremity run-off with a single injection and single run.
- Unique X-ray tube and cooling system that allows for full-resolution imaging for longer periods of time.
- HD flat panel monitors on an articulating arm allow comfortable viewing of precise images.
- Remote service connectivity to enable system performance diagnostics.
- 1k x 1k high resolution imaging technology on a mobile system.
GE OEC 9900 Elite Specification:
Generator
- 60 kHz high frequency.
- 15 kW full-wave.
- Up to 120 kVp.
- Up to 75 mA for radiographic film exposure.
- Continuous high level fluoro up to 20 mA.
- Pulsed fluoro mode.
- Pulsed fluorography mode up to 40 mA.
- Digital spot up to 75 mA.
- Full power from outlet:
- 50 Hz or 60 Hz.
- 120V-12A or 240V-10A.
X-Ray Tube
- Rotating anode X-ray tube.
- Focal spots: 0.3 mm and 0.6 mm.
- Anode heat capacity: 300,000 HU.
- Anode cooling rate: 85,000 HU/min.
- Housing heat capacity: 1,600,000 HU.
- Standard housing cooling 15,000 HU/min.
- Passive housing cooling system: 22,500 HU/min. (Standard on 12 inch (31 cm) I.I. systems.
PreView™ Collimator
- On-screen collimator position indication.
- PreView™ iris collimator.
- PreView™ Tungsten rotatable double leaf collimator.
- Adjusts collimators without X-ray exposure.
Fluoroscopy Mode
- Focal spot: 0.3 mm.
- kVp range: 40 – 120 kVp.
- mA range: 0.2 – 10 mA normal mode.
- mA range: 1.0 – 20 mA HLF. (high level fluoro.)
- Auto and manual fluoro modes.
- Continuous, one-shot or pulsed operation.
- AutoTrak™ ABS varies mA, kVp, camera gain.
Pulsed Fluoroscopy Mode
- Focal spot: 0.3 mm.
- kVp range: 40 – 120 kVp.
- mA range: 0.2 – 10 mA.
- Pulse rate: 1, 2, 4, or 8 pulses per second.
- Pulse width: 25 or 50 milliseconds.
- AutoTrak™ ABS, mA, kVp, camera gain.
- Reduces X-ray dose to patient and operator.
High Level Pulsed Fluoro
- Vp range: 40 – 120 kVp.
- mA range: 1 – 40 mA.
- Pulse width: 25 or 50 milliseconds.
- Pulse rate: 1, 2, 4, or 8 pulses per second.
- AutoTrak™ ABS, mA, kVp, and camera gain.
Digital Spot Mode
- kVp range: 40 – 120 kVp.
- mA range: Up to 75 mA.
- Automatic exposure termination and automatic image save.
Video Camera
- High resolution 1k x 1k CCD camera.
- Full frame capture.
- Motorized rotation.
- On-screen orientation indicator. (real-time feedback without fluoro.)
- Left-right image reversal.
- Top-bottom image reversal.
Video Monitors
- Dual 18” (46cm) display anti-glare, LCD flat panel monitors mounted on an articulating arm.
- 22” horizontal travel.
- 7° up/10° down.
- Monitors viewable from all four sides of workstation.
- Horizontal and vertical viewing angle 170°.
- 700 CD/M2 maximum brightness.
- Touch screen system control.
- 1280 x 1024 high resolution monitors.
- Ambient room-light compensation.
- Integrated color monitor for display of VGA, DVI, DVI-D, S-VHS.
C-Arm Dimensions
- Height: 69.7 / 87.7 in. (1770 / 2228 mm.)
- Width: 33.5 in. (851 mm.)
- Length: 77.8 in. (1976 mm.)
- Weight: 610 lbs. (277 kg.)