HP CodeMaster XL+

24-Hour Quotes

Pricing up to 50% below the cost of new,
with service and warranty included.
Download Specifications

HP CodeMaster XL+ Features

The HP Codemaster XL+ is a high-performance Defibrillator monitor. The HP Codemaster XL+ offers multi-functional electrodes that allow you to do pacing and defibrillation with the same pads. At the same time, the system offers a hands-free operation that allows for remote defibrillation. The Defibrillation system has built-in paddles for pediatric and adult patients. With its easy 1-2-3 operation, the system is easy to use and offers a speedy response in an emergency. The system can charge from 0 to 360 in 5 seconds and store up to 28 events in the memory. The HP Codemaster XL Plus has a bright 5-inch screen that can tell you the condition of the patient at a glance.

  • Defibrillator with ECG and recorder
  • Provides 1-2-3 operation
  • Built-in pediatric paddles under slide-off adult paddles
  • Preset heart rate alarms
  • High-capacity battery
  • Built-in diagnostics

HP CodeMaster XL+ Specifications

Dimensions

  • Height: 7.9” (20 cm)
  • Width: 11.8” (30 cm)
  • Depth: 15.6” (39.7 cm)
  • Weight: 24 lbs (10.9 kg)

Defibrillator

  • Waveform: Damped sinusoidal (Lown)
  • Output Energy: 2, 3, 5, 7, 10, 20, 30, 50, 70, 100, 150, 200, 300, and 360 joules
  • Charge Control: Push-button on the apex paddle and on the front panel
  • Charge Time: Less than 5 seconds to 360 joules with battery present. Less than 15 seconds to 360 joules on AC only.
  • Armed Indicators: Charge done tone, charge done lamp on apex paddle, and available energy indicated on display.
  • Paddle Contact Indicator (optional): A 3-color LED bar graph array on the STERNUM paddle indicates the quality of defibrillator paddle contact before discharge.
  • Paddles: Standard paddles are anterior/anterior, adult, and pediatric. Adult electrodes (83 cm2) slide off to expose pediatric electrodes (21 cm2). The paddle cord is 10 ft (3 m). Full range of internal paddles available.

Monitor

  • Inputs: ECG may be viewed through paddles or patient cable. Lead I, II, III, or PADDLES selectable. Additional leads (aVR, aVF, aVL, V Leads) and PADS are available. Monitor and recorder indicate the selected ECG source
  • Lead Fault: LEADS OFF message and dashed baseline appear on the monitor if a lead becomes disconnected
  • Common Mode Rejection: Greater than 100 dB measured as per AAMI standards for cardiac monitors (EC13)
  • Display Size and Type: 5-inch (12.7 cm) diagonal CRT for 4 seconds of ECG data on screen; non-fade, fixed trace. Scrolling trace is selectable
  • Sweep Speed: 25 mm/sec nominal
  • Frequency Response: 0.5 to 40 Hz
  • Heart Rate Display: Digital readout on the monitor from 15 to 300 BPM.
  • Heart Rate Alarms: There are three pre-set pairs of high and low heart rate alarm limits from 20 to 280 BPM. (Configurable pairs are optional.)
  • ECG Output: 1V/mV
  • Patient Cable Length: 10 ft (3 m)

Thermal Array Recorder

  • Event Summary (optional): Stores and prints 3 seconds pre- and 8 seconds post-critical event data for up to 28 events. Data is retained after the unit is turned off
  • Annotates: Time, date, HR, event marker, ECG mode, defibrillator mode, selected energy, actual delivered energy, peak current, and patient impedance
  • Speed: 25 mm/sec.
  • Paper Size: 50 mm by 30 m (100 ft)
  • Recorder Mode: Automatically documents events and ECG during defibrillation episodes. The recorder can be configured to run in either real-time or with a six-second delay
  • Frequency Response: 0.5 to 40 Hz or 0.05 to 150 Hz selectable

Battery

  • Type: Rechargeable sealed lead-acid battery. 4 Ah, 12 V nominal
  • Charge Time: 2 hours to 90% of full capacity. 18 hours to 100% capacity. Repeated charging to less than 100% will reduce the useful life of the battery.
  • Capacity: 2 1/2 hours monitoring or fifty (50) full-energy discharges or 1-hour monitoring and recording.
  • Battery Indicators: Illuminated LED indicates the battery is charging. A LOW BATTERY message appears on the monitor when limited battery capacity remains.

External Pacemaker (Optional)

  • Current Pulse Amplitude: 10 mA to 200 mA.
  • Pulse Width: 20 msec.
  • Rate: 40 ppm to 180 ppm.
  • Modes: Demand or fixed rate.
  • Refractory Period: 40 to 80 ppm 340 msec; 90 to 180 ppm 240 msec.

SpO2 (Optional)

  • Measurement Range: 0 to 100%
  • Accuracy with HP M1190A Sensor: 1 standard deviation, 65-80%: ±2.5%, 80- 100%: ±1.5%, resolution: 1%
  • Averaging: 8 beats
  • SpO2 Alarm Limits — Range: 100/90, 100/85, 100/80
  • SpO2 Alarm Delay: Ten seconds after the value drops below the low alarm setting.
  • INOP Alerts: Triggered by the disconnected sensor, noisy signal, light interference, or a low signal.
  • Pulse Rate Measurement Range: 30 to 300 bpm ± 1%; resolution 1 bpm.
  • Pulse Amplitude Indicator: Indicates pulsatile activity.

 

Banner

Questions about our Defibrillators?

Soma Tech Intl offers a wide range of defibrillators. If you have any questions about any of our defibrillators or need a quick quote, call us and one of our knowledgeable sales representatives will help you.

Looking to sell your defibrillators? Soma ensures your facility gets top dollar for your equipment and also gives the option for trade-in credit.

1-800-GET-SOMA
Contact Us