The Zoll R Series is an ALS defibrillator, BLS defibrillator, and monitor that can provide CPR, defibrillation, and pacing therapies. The Zoll R is not just known as being a defibrillator it offers 3-lead ECG, pacing, end-tide Co2, Non-invasive Blood Pressure (NIBP), and SpO2 Monitoring. With wireless connectivity, the R Series defibrillator can give health providers a quick overall snapshot of the patient’s health via a PC or mobile device. With a color display screen, you can view the CPR dashboard which can show depth, rate, and visual indicators of compression releases. Request a quotation for a price or a certain configuration/package. Soma also offers crash carts that can be used with this series defibrillator. The previous model of the Zoll Defibrillator is the Zoll E Series.
- Always Code-Ready
- Remote viewing and administration from a PC or mobile device
- History of readiness logs for the Joint Commission
- Readiness check includes defib, pacing, and ECG modules; AC power; battery; 30-joule shock test; electrodes attached and not expired
- Customizable dashboard
Zoll Defibrillator R Series Specifications
Dimensions
- Height: 8.2” (20.8 cm)
- Width: 10.5” (26.7 cm)
- Depth: 12.5” (31.7 cm)
- Weight: 15.2 lbs (6.9 kg)
Power
- Voltage: 100-120 V AC
- Frequency: 50/60 Hz
- Battery: Rechargeable Lithium-Ion battery pack
Defibrillation
- Waveform: Rectilinear Biphasic
- Patient Impedance Range: 15 to 300 ohms
- Energy Selections: 1 to 10, 15, 20, 30, 50, 75, 100, 120, 150, and 200 joules selected using controls on the front of the defibrillator or sternum paddles. (Note: When using appropriate pediatric resuscitation electrodes, the 75-joule setting is replaced by 70- and 85-joule settings.)
- Smart Step Energy Levels: Automatically escalates energy through a configured adult or pediatric protocol
- Energy Display: Shown on the monitor for both selected and delivered
- Charge Time: Less than 7 seconds with a new, fully charged battery (first 15 charges to 200 joules); longer charge times may result in a depleted or older battery
- Synchronized Mode: Synchronizes defibrillator pulse to patient’s R wave. “SYNC” message displayed on monitor and markers shown on both monitor and recorded ECG
- Charge Controls: Control from the front of the defibrillator or apex paddle
- Paddles: External apex/sternum paddles; adult plates slide off to expose pediatric electrode surface
- Code Readiness Testing (OneStep): Verifies defibrillator hardware, therapy delivery cable (with both paddles and electrodes), electrode condition, and expiration (with select OneStep electrodes) without the need for a separate test fixture.
ECG Monitoring
- Patients Connection: 3-lead ECG cable, 5-lead ECG cable, paddles, or hands-free electrodes; selectable by the front panel switch
- Input Protection: Fully defibrillator protected. Circuits designed to prevent distortion of ECG signal by pacer pulse
- Implanted Pacemaker Spike Display: Circuits designed to detect most implanted pacemaker spikes and display a marker on the ECG trace
- Bandwidth: 0.5 to 21 Hz (-3dB) standard; 0.05 to 150 Hz diagnostic with configurable options of 0.5 Hz to 40 Hz or 1 Hz to 21 Hz
- Lead Selection: I, II, III aVR, aVL, aVF, V, P1, P2, P3 with OneStep Pacing electrode
- ECG Size: 0.5, 1.0, 1.5, 2.0, or 3.0 cm/mV display on the monitor
- Heart Rate Display: 0 to 300 bpm ±5%
- Heart Rate Alarm: User selectable for tachycardia at 60 to 280 bpm; for bradycardia at 20 to 100 bpm. On/Off status displayed on the screen.
Display
- Screen Type: Color, VGA liquid crystal display (LCD)
- Screen Size: 6.5 inches (16.5 cm) diagonally
- Sweep Speed: 25 mm/sec
- Viewing Time: 5 seconds with the standard display format
- Channels: 3
- Information: Heart Rate, Leads/Pads, Alarm On/Off, Selected Energy, Delivered Energy, User Prompts and Warnings, Code Readiness Test Results, SpO2, Non-invasive Blood Pressure, EtCO2, Pacer Functions, Code Markers, CPR Dashboard
Battery Packs
- Type: 10.8 V (nominal) rechargeable lithium-ion
- Capacity: 5.8 amp hours
- Weight: 1.7 lb (0.77 kg)
- Recharge Time: 5 hours or less with an integral charger
- Operating Time: >4 hours of continuous ECG monitoring; 100 maximal energy (200 joules) discharges; 3.5 hours of continuous ECG monitoring and pacing at 60 mA, 80 ppm
Recorder
- Technology: 90 mm thermal array; 80 mm grid width
- Speed: 25 mm/sec, 6-second delay
- Zoll Printing Modes: Manual or automatic
- Annotations: Time, date, defibrillation energy, patient impedance, heart rate, pacer output, QRS synchronization marker, ECG size, ECG lead, alarm, defibrillator test results, analyze ECG, ECG bandwidth
External Pacing
- Type: VVI demand; asynchronous (fixed rate) when used without ECG leads or in asynchronous (ASYNC) pacing mode
- Pulse: Rectilinear, constant current: 40 ms ±2 ms; variable 0 to 140 mA ±5% or 5 mA, whichever is greater. The rate is variable from 30 to 180 ppm ±1.5%
- Output Protection: Fully defibrillator protected and isolated
- Zoll Pacing: Eliminates the need to connect separate ECG leads and or a cable when used in conjunction with official electrodes.
Pulse Oximetry with Masimo SET Technology
- Saturation Range: 1-100% (%SpO2 ) with a resolution of 1%
- Pulse Rate Range: 25-240 ppm with a resolution of 1 ppm
- Saturation Accuracy: Non-motion conditions ±2% for adults/pediatrics; ±3% for neonates. During motion ±3% for all patients
- Pulse Rate Accuracy: Non-motion conditions ±3 ppm. During motion ±5 ppm.
Mainstream CO2 Capnostat 5 Sensor
- Principle of Operation: Nondispersive infrared (NDIR) single-beam optics, dual-wavelength, no moving parts
- Warm-up Time: Full specifications within 2 minutes at an ambient temperature of 25°C. Capnogram in 20 seconds
- Environmental: Zoll Operating Temperature: 0°C to 45°C, Storage and Shipping Temperature: -40°C to 70°C.
Sidestream CO2 LoFlo Sensor
- R Series Principle of Operation: Nondispersive infrared (NDIR) single-beam optics, dual-wavelength, no moving parts
- R Series Warm-Up Time: Full specifications within 2 minutes at an ambient temperature of 25ºC. Capnogram in 20 seconds
- R Series Environmental: Operating Temperature: 0°C to 40°C, Storage and Shipping Temperature: -40°C to 70°C.
NIBP
- Zoll R Series Patients Type: Adult, Pediatric
- Zoll R Series Method: Oscillometric
- Zoll R Series Control: Automatic and manual non-invasive blood pressure measurement.
WiFi Capable
- WiFi 802.11 a/b/g/n Ambicom-specific 1100C-CF Card P/N 8005-000101-01 compatibility
- Typical Readiness File Data Size: 750K
- Zoll Code Data File: 1.2 MB.
Accessories
- All equipment accessories can be found on the Soma medical equipment accessories and parts website.
- 8009-0762-01 – OneStep Leads – AHA
- 9650-0903-01 – Service Manual
- 8900-000219-01 – OneStep Pediatric CPR Electrode 1ct
- 8900-000220-01 – OneStep Pediatric CPR Electrode 8ct
- 8900-0214-01 – Resuscitation Electrode 8ct
- 8009-0750 – Pacing Cable
- 8900-0213-01 – CPR Resuscitation Electrode 8ct
- 8900-0211-01 – Resuscitation Electrode 8ct
- 8009-0751-01 – SeeThru CPR Simulator