Drager Air-Shields Resuscitaire RW Features

The Drager Air-Shields Resuscitaire RW infant warmer combines an effective warming therapy platform with the components you need for clinical emergency resuscitation. The Drager Resuscitaire offers a blender, suction, flowmeter, and positive pressure mounted on the bed for easy accessibility. It features a Silica Quartz Heater that provides complete, even, and quick heating. A parabolic reflector helps distribute the heat evenly over the entire mattress area.

  • Exceptional access from either side.
  • Configure to your department’s needs.
  • Easily access suction.
  • Efficiently adjust mattress position.
  • The head of the warmer module can swivel up to 90 degrees.
  • Automatic Pre-Warm Mode allows long-term, controlled warming of the mattress with no nuisance alarms.

Drager Air-Shields Resuscitaire RW Specifications

Physical Attributes (Without Options / Accessories)

  • Height: 72 in (183 cm)
  • Width: 26.5 in (68 cm)
  • Depth: 44 in (112 cm)
  • Weight: (without options /accessories) 220–280 lbs (100–127 kg)

Mattress

  • Height From Floor: 39.4 in (100 cm)
  • Width: 21.0 in (53.3 cm)
  • Length: 26.0 in (66.0 cm)
  • Thickness: 1.0 in (2.54 cm)
  • Maximum Capacity: 15 lbs (4.54 kg)

Maximum Power Requirements

  • Model 120V: 120 V, 50–60 Hz, 750 W
  • Model 220/240V: 220–240 V, 50–60 Hz, 750 W )

LED Examination Light

  • Illumination: > 0.11 lumens / cm2 (100 ft. Candles)

Controller Heating Alarms

  • Check patient System alerts for 5 minutes in Manual Mode every 30 seconds after 10 minutes
  • Baby temperature ±1° C from Set Point
  • High-temperature Skin Temp. 39.0 ±0.2 °C
  • Probe Short or open circuit / No probe
  • System fail Indicates System Fail
  • Power fail AC Power Interruption

Alarm Silence / Reset Intervals

  • Check patient Resets clock for 10 minutes in manual mode
  • Baby temperature 10 minutes
  • High temperature 2 minutes
  • Procedural silence Presilences baby temp alarm for 5 minutes

Set Temperature / Heater Output

  • Set Temp Range: 34–38 °C (>37.0° override)
  • Heater Output: 0–100%, 10% increments
  • Skin Temp Display: 18–43 °C
  • Accuracy: ±0.2 °C (31 to 37° C)

Resuscitation Module

  • Wall Supply Pressure: 40–75 psi (275–517 kPa)
  • Cylinder Pressure: 2,900 psi max (19 994 kPa)

Patient Gas Supply

  • Flow Control Range: 0–15 LPM
  • Airway Pressure Limit: Adjustable 0–50 cm H2O (0–4.9 kPa); Internal preset limit 60 cm H2O (5.9 kPa)

Soma Tech Intl offers the Resuscitaire RW Infant Warmer up to 50% below OEM prices with the same service and warranty as new. The Drager infant warmer is not only technically refurbished but also cosmetically refurbished to make it work and look like new. When the refurbishing process starts on the Resuscitaire RW, it is carefully inspected and tested by our own in-house biomedical engineers who are highly skilled and certified to work on infant warmers. If necessary, parts are replaced to make sure that all aspects of the Resuscitaire RW Infant Warmer are to the original engineering manufacturer’s specifications. This ensures that the unit is working the same way that it originally left the manufacturer. After the Air-Shields warmer is working like new it undergoes a special cosmetic restoration process. The Resuscitaire RW is cleaned, minor scratches and dents are repaired, it’s painted, and new decals are replaced if necessary. After this strenuous refurbishing process, the unit functions and looks new. Soma Tech Intl is ISO 13485 certified and ensures that the best quality is given to all capital medical equipment that they sell. Before the Drager Resuscitaire RW is labeled patient-ready and packed up for shipment, it goes through one last quality control test that makes sure all aspects are again working as they should. If you are looking to buy a refurbished infant warmer contact Soma at [email protected] or call us at 1-800-438-7662.

Soma Tech Intl is actively looking to purchase a Resuscitaire RW Infant Warmer. If you or your facility is looking to sell your Air-Shields warmer, be sure to contact Soma Tech Intl. Soma has a dedicated and experienced purchasing department that helps you through the entire process. Selling your used or pre-owned Drager equipment takes out the middleman in the equation. This also ensures that your medical facility gets top dollar for your equipment. Soma is 100% HIPPA compliant and makes sure that your equipment gets to our facility in the same condition that it left yours. Soma Tech Intl also gives the option for trade-in credit on your medical equipment. If you have medical equipment you would like to sell to Soma, give us a call.

Banner

Questions about our Infant Warmers?

Soma Tech Intl offers a wide range of infant warmers. If you have any questions about any of our infant warmers or need a quick quote, call us and one of our knowledgeable sales representatives will help you.

Looking to sell your infant warmers? Soma ensures your facility gets top dollar for your equipment and also gives the option for trade-in credit.

1-800-GET-SOMA
Contact Us