Drager Fabius GS Anesthesia Machine

December 7, 2017
Drager Fabius GS - Anesthesia Machine - Soma Technology Inc

Dräger Fabius GS Features:

  • Proven Ventilation Versatility
  • Electronic Gas-Flow Measurement
  • Compact, Convenient Breathing System
  • Intelligent Cable Management

Dräger Fabius GS Specifications

Weight:

  • 224 lbs. (101.6 kg) (base unit without vaporizers or cylinders.)

Dimensions:

  • (W) 89.5 cm x (H) 130 cm x (D) 82 cm (35.2 x 51.2 x 32.3 inches)

Power Supply:

  • 100 – 240 VAC, 50/60 Hz, 2.3 A max.
  • Battery (supports ventilator and monitor) > 45 min.

Ventilator:

  • E-vent Electronically controlled, electrically driven.

Operating Modes Standard:

    • Manual/Spontaneous.
    • Volume Control (IPPV).
Options:
    • Pressure   Control. (PCV)
    • Pressure Support. (PS)
    • Synchronized Volume   Controlled Ventilation w/PS. (SIMV/PS)

Breathing Frequency:

  • 4 to 60 bpm.

Max. Minute Volume (MV):

  • 25 L/min.

PEEP:

  • 0 – 20 cmH2O.

Inspiration / Expiration Ratio:

  • (Ti:Te) 4 : 1 to 1 : 4.

Pressure Limiting (Pmax):

  • 15 – 70 cmH2O.

Tidal Volume (Vt):

  • 20 – 1400 mL in Volume Control.
  • 20 – 1100 mL in SIMV/PS.

Inspiratory Pause (Tip:Ti):

  • 0 – 50 .

SIMV Inspiratory Time(Tinsp):

  • 0.3 – 4.0 sec.

Inspiratory Pressure (Pinsp):

  • PEEP + 5 to 65 cmH2O.

Inspiratory flow (InspFlow):

  • 10 – 75 L/min in Volume and Pressure Control.
  • 10 – 85 L/min in Pressure Support.

Pressure Support Level (Δ PPS) PEEP:

  • + 3 to 20 cmH2O Min. Frequency for 3 – 20 bpm and “ OFF ”.

Apnea-Ventilation:

  • ( Freq. Min.)Trigger 2 – 15 L/min.

Safety functions:

  • Sensitive Oxygen Ratio Controller (S-ORC) guarantees a minimum O2 concentration of 23% in an O2/N2O mixture. N2O cut-off if O2 fresh gas valve is closed or if O2 flow is less than 0.2 L/min.

Safety functions:

  • Sensitive Oxygen Ratio Controller (S-ORC) guarantees a minimum O2 concentration of 23% in an O2/N2O mixture. N2O cut-off if O2 fresh gas valve is closed or if O2 flow is less than 0.2 L/min.
  • Audible and visual (flashing red LED)indication in case O2 pressure drops below 20 psi (1.38 bar) ± 4 psi (0.27 bar). In case of electricity and battery failure, manual ventilation, gas delivery and gent delivery are possible. Positive pressure relief valve opens at 75 ± 5 cmH2O. Negative pressure relief valve opens at – 7.5 to – 9 cmH2O.

Range of fresh gas flow indicators:

  • 0.00 to 12.0 L/min.

Total fresh gas flow meter:

  • 0 to 10 L/min, calibrated with a mixture of 50 % O2 and 50 % N20  mixture.

O2 flush at 87 psi (6 bar):

  • max. 75 L/minat 41 psi (2.8 bar): min 25 L/min.

Vaporizer Mount:

  • Dräger or SelectatecR mount.

Monitoring:

  • Continues monitoring of inspiratory O2 concentration (can be switched off by Service) breathing frequency, tidal volume, minute volume, mean or plateau pressure, peak airway pressure as well< as PEEP. In addition, all fresh gas flow information is displayed as virtual flow tubes.

Serial interface:

  • 1 x RS 232 (standard); 1 x RS 232. (option)

Have you used this anesthesia machine? Do you like other anesthesia machines?

For more anesthesia machines, please click here.

For more products by Drager, please click here.