GE Dash 3000 Multiparameter Monitor

March 21, 2017
GE Dash 3000 Multiparameter Monitor

GE Dash 3000 Features:

  • Durable design creates a dependable solution for demanding transport applications, including air transport.
  • System consistently produces the most accurate, reliable NIBP information.
  • Ideally suited for NICU, PICU and hypertensive patients.

GE Dash 3000 Specifications:

Dimensions

  • Height: 26 cm.
  • Depth: 20 cm.
  • Width: 28 cm.
  • Weight: 5.5 kg.

Display

  • Size: 22 cm (diagonal).
  • Type: active-matrix color TFT.
  • Resolution: 640 x 480 pixels.
  • Number of traces: 6 maximum.
  • Number of seconds/trace: 4.9 at 25 mm/sec.
  • Sweep Speed: 6.25, 12.5, 25 mm/sec (with erase bar).
  • Information window:displays non-real-time information without obstructing the display of real-time information.
  • Display organization: prioritized by parameter.

Controls

  • Trim Knob® control.
  • Five hard keys: Silence Alarm, Graph Go/Stop, NIBP Go/Stop, function (zero all) and Power On/Off.

Alarms

  • Categories: patient status and system status.
  • Priority: 4-levels crisis, warning, advisory, message.
  • Notification: audible and visual.
  • Settings:default or user-defined.
  • Silencing: 1 minute, current alarm only.
  • Pause: 5 minutes in adult ICU mode, 3 minutes in Neonatal ICU mode, and 5, 15, minutes or permanent pause in OR mode.

ECG

  • Standard leads available: I, II, III, V, aVR, aVL, and aVF.
  • Leads analyzed simultaneously: I, II, III and V (multi-lead).
  • Lead fail: identifies failed lead.
  • Alarms: user-selectable upper and lower heart rate limits.

Respiration

  • Measurement technique: impedance variation detection. Range respiration rate: 0-200 breaths per minute. User-selectable upper and lower respiration rate limits, and user-selectable apnea limit.

Temperature

  • Number of channels: 2.
  • Resolution: ±0.1°C.
  • Alarms: user-selectable upper and lower limits for T1, T2.

Invasive Blood Pressure

  • Number of channels: 2.
  • Range: -25mmHg to 300mmHg.
  • Alarms: user-selectable upper and lower limits for systolic, diastolic, and mean pressures.

NIBP

  • Measurement technique: oscillometric.
  • Displayed parameters: systolic, diastolic, and mean pressures, time of last measurement.
  • Measurement modes: manual, auto, and stat in Adult ICU and OR modes, manual and auto in neonatal mode.
  • Systolic range: 30-275 mmHg adult, 30-235 mmHg pediatric, 30-135 mmHg neonate.
  • Diastolic range: 10-220mmHg adult, 10-220mmHg pediatric, 10-110 mmHg neonate.

Pulse Oximetry

  • Parameters monitored: SpO2 and peripheral pulse rate.
  • SpO2 range: 50-100%.
  • PPR range: 30-300 beats per minute.
  • SpO2 accuracy: ±2%, 70 – 100% SpO2, ±3% (50-69% SpO2).
  • PPR Accuracy: ±3 beats per minute.