The Maquet Datascope CS300 IABP with IntelliSense combines fiber-optic speed with automatic in vivo calibration. The result of the cs300 IABP is faster time to therapy, faster signal acquisition, and faster adaptation to rate and rhythm changes. Maquet has the only fiber-optic IABP and catheter system that automatically calibrates in the patient after insertion and automatically recalibrates in vivo every two hours or sooner should patient or environmental conditions change.

  • Faster inflation and deflation speed
  • CS300 has true one-button start-up
  • Automatically calibrates the fiber-optic pressure sensor in the patient and recalibrates every 2 hours or sooner should patient or environmental conditions change
  • Automatically evaluates and selects the best lead and trigger source
  • Automatically sets optimal timing
  • Automatically adjusts to changes in patient conditions without clinician intervention
  • A Maquet fiber-optic IAB catheter
  • Conventional fluid-filled IAB catheters

Datascope CS300 IABP Specifications

Dimensions

  • Size on Cart: 43.1” H x 16.8” W x 22.3” D (109 cm H x 42.7 cm W x 56.6 cm D)
  • Size off Cart: 26.9” H x 10.8” W x 20.5” D (68.3 cm H x 27.4 cm W x 52.1 cm D)
  • Console Weight: 84.8 lbs. (38.4 Kg) nominal (includes S.D., CRM, and He tank)
  • Monitor: 9.5 lbs. (4.3 Kg) nominal
  • Hospital Cart Weight: 52.4 lbs. (23.8 Kg) nominal
  • Internal Battery: 34 lbs. (15.4 Kg) nominal
  • Storage Bag: 4.6 lbs. (2.1 Kg) nominal (includes doppler and doppler holder)
  • UTS Version: Rugged base which attaches to docking station (DS)
  • Dimensions: 30.0” H x 13.2” W x 22.5” D (76.2 cm H x 33.5 cm W x 57.2 cm D)
  • Console Weight: 135.3 lbs. (61.4 Kg) (includes S.D., CRM, He tank, Monitor, Battery)
  • Lightweight DS*: 17.8” (45.1 cm) x 20.0” (50.8 cm); 16.3 lbs (Suggested Option)

Environmental

  • Op. Temp.: 10°C – 40°C
  • Op. Humidity: 5 – 95% (R.H.) non-condensing
  • Op. Altitude: 0 – 12,000 feet (3,657 m); automatic altitude correction for IAB

General

  • Service Diagnostics: Built-in software for system analysis and troubleshooting
  • Modem Data Rate: Up to 9,600 baud
  • Modem Certifications: Registered with FCC and accepted in ~ 89 countries
  • Fiber-optic signal Detected when sensor is connected to receptacle acquisition:
  • Low-level Fiber-optic Enacted when appropriate cable plugged in
  • Pressure Output: (electrically isolated)
  • Pressure Range: 0 to +300 mmHg (minimum)
  • Accuracy: 4 mmHg or 4%, whichever is greater
  • Frequency Response: DC to 26Hz + – 15% (+0 to -3dB)
  • Excitation: 4 to 8 Volts DC minimum
  • Noise: .2 mmHg rms (0 to 26Hz bandwidth)
  • External Mon. Inputs: ECG: 1 V/mV (nominal); AP: 1 V/100 mmHg (nominal)
  • ECG/BP Output: Phone Jack: ECG 1V / mV, BP 1V/100 mmHg
  • Mains Voltage: 100-120 VAC ± 10% or 220-240 VAC ± 10%
  • Mains Frequency: 50/60 Hz ± 3 Hz
  • Internal Battery: 24 VDC (nominal), 17.2 Amp-hour, approx. 3 hrs. @ 90 bpm
  • Battery Type: Maintenance free; Sealed lead-acid
  • System Compressor: Dual head diaphragm pump with brushless DC motor
  • IAB Helium (He+): Medical-grade; 99L Refillable (2200 psi) or 140L Disposable (2200 psi)
  • He+ Endurance (nominal) 2 mos. continuous operation – 24 hrs./day
  • Condensate Removal: Fully automatic condensate removal and disposal
  • Color Display: Color TFT Liquid Crystal Display (LCD) 8.3”(21cm)W x 6.2”(15.8cm)H; up 45°, 10.4” diagonal (26.4 cm down 55°, right 70°, left 70° viewing angle; Rotates 330°; Tilts 180°; Detachable; Laptoplike closure for storage and protection; Remote monitor mount (optional)
  • Preferences Menu: User may select display sweep speed (25 or 50 mm/sec), brightness (low, med., high); balloon wave form (on/off); ECG inflation markers (on/off); flashing alarms (on/off); printer preferences, set date and time)
  • Operation Modes: Auto, Semi Auto, Manual
  • ECG Trigger: Threshold dynamically adjusted by system for high sensitivity and selectivity of the R-wave detection; Minimum =120μV ± 20μV at normal gain; 40μV at max. gain
  • Pressure Trigger: Default trigger threshold is automatically adjusted to 38% of the systolic pulse height; 7 mm minimum Manual threshold mode: User adjustable between 7 and 30 mmHg ± 3 mmHg
  • Pacer A Trigger: R-wave detection (as above) except pacer blanking is extended to 100 ms
  • Pacer V/A-V Trigger: V Pacer: fixed at rate up to 185 bpm (no demand pacing)
  • A-V Pacer: fixed at rate up to 125 bpm (no demand pacing) with A-V intervals between 80-224 ms
  • Internal Trigger: Variable mode: 40-120 bpm; Normal mode: 80 ± 1 bpm
  • Tall T-Wave Rejection: Rejects all T-Waves where Q-T interval is <300 ms (ECG and Pacer A mode) and the amplitude is <70% of QRS input amplitude
  • Pacer Rejection: Rejects all pulses of amplitude ± 2.0 mV to ± 700 mV (ECG and Pacer A mode) and durations between 0.1 ms to 2.0 ms with: 1) No tail; 2) 100 ms time constant tail < 1 mV; 3) 25 ms time constant tail < 1 mV; 4) 4 ms time constant tail < 2 mV
  • ECG Leads: In Auto Operation Mode: I, II, III, External
  • In Semi-Auto Mode: I, II, III, AVR, AVL, AVF, V, External (12 lead compatibility)
  • ECG Gain (default): 1 V output per 1 mV input ±5% (waveform automatically scaled to occupy ECG display window)
  • Gain (variable): 0.15 to 3.0 cm/mV ±20% (autoscaling disabled)
  • Frequency Response: 0.5-12 Hz (display); 0.5-135 Hz (Output to External Monitor)
  • Defibrillator Protection: Discharge level 360 J (trace returns to screen in 5 sec max)
  • ESIS: Automatic suppression with internal ECG amplifier
  • AP Source Selection: Direct/External (menu based)
  • AP Input Sensitivity: 5.0μV/V/mmHg
  • Excitation: +5 VDC ± 5% @ 130 mA (max)
  • Frequency Response: DC to 12 Hz (display)