Philips BV Pulsera Features

The Philips BV Pulsera C-Arm is a multi-application mobile X-ray imaging system for the most challenging interventional procedures in Pain Management, General, Orthopedic, Vascular, Neurovascular and Cardiac surgeries. The Philips BV Pulsera is a powerful fluoroscopy system with a high resolution CCD camera, outstanding image quality with low X-ray dosage, crisp, clear images and superior penetration power.

Philips BV Pulsera Specifications

X-Ray System

Specialty Packages Available

  • Extended processing.
  • Vascular functions.
  • Extended vascular functions.
  • Cardiac Pulsed functions.

Generator

  • 80 kHz High frequency.
  • 7.5 kW full-wave.
  • Up to 120 kVp.
  • Up to 60 mA for radiographic film exposures.
  • Continuous fluoro boost mode up to 20 mA.
  • Pulsed fluoro mode.
  • Pulsed fluorography mode up to 60 mA.
  • Full power from outlet:
    • 50 Hz or 60 Hz.
    • 100V-20A to 240V-10A.

X-Ray Tube

  • Rotating anode X-ray tube.
  • Focal spots: 0.3 mm and 0.6 mm.
  • Anode heat capacity: 300,000 HU.
  • Anode cooling rate: 70,000 HU/min.
  • Housing heat capacity: 1,900,000 HU.
  • Anode diameter: 2.8 in.
  • Anode angle: 10°.

Collimator

  • Iris collimation with dual opposing lead shutters allowing elliptical, round and rectangular collimation.
  • Minimum beam size < 5 X 5 cm2.
  • Iris and shutters are continuously variable.
  • All functions remotely controlled from the C-Arm control panel.

Fluoroscopy Mode

  • Focal spot: 0.3 mm and 0.6 mm.
  • kVp range: 40 – 120 kVp.
  • mA range: 0.2 – 20 mA continuous High Definition fluoro boost mode.
  • Auto and manual modes.
  • Continuous or Pulsed operation.
  • APF varies mA, kVp and camera gain.
  • User specific APF tables.

Pulsed Fluoroscopy Mode

  • Half Dose Fluoroscopy.
  • Quarter Dose Fluoroscopy.
  • Focal spot: 0.6 mm.
  • kVp range: 40 – 120 kVp.
  • mA range: 0.4 – 12 mA.
  • Pulse rate: 6.25 or 12.5 pulses per second.
  • Pulse width: 11 to 37 milliseconds.
  • Computer controlled APF, mA, kVp and camera gain.

Pulsed Fluorography Mode

  • Focal spot: 0.6 mm.
  • kVp range: 40 – 110 kVp.
  • mA range: Up to 60 mA.
  • Pulse rate: 3 to 30 pulses per second. (optional)
  • Pulse width: 8.0 / 9.5 / 11.1 milliseconds.
  • Computer controlled camera iris, mA, kVp, & camera gain.

Digital Exposure Mode

  • Focal spot: 0.6 mm.
  • kVp range: 40 – 110 kVp.
  • mA range: 1.0 – 75 mA.

Radiographic Mode

  • Focal spot: 0.6 mm.
  • kVp range: 40 – 120 kVp.
  • Fixed 60 mA.
  • 0.6 mm – mAs range: 3.2 – 125 mAs.

Video Imaging System

Image Intensifier

  • 9 in Image Intensifier
    • Tri-mode 9 in/7 in/5 in image intensifier
      • 9 in.: 1.6 lp/mm
      • 7 in.: 2.1 lp/mm
      • 5 in.: 2.9 lp/mm
    • DQE: 65% (typical)
  • 12 in Image Intensifier (optional)
    • Tri-mode 12 in/9 in/7 in image intensifier
      • 12 in.: 1.2 lp/mm
      • 9 in.: 1.4 lp/mm
      • 7 in.: 2.0 lp/mm
    • DQE: 65% (typical)

Video Camera

  • High resolution CCD camera.
  • 525 line/frame.
  • Full frame capture.
  • 360° motorized rotation.
  • Left-right image reversal.
  • Top-bottom image reversal.
  • Negative mode.
  • Computer controlled features: (optional)
    • Gain.
    • Blanking.
    • Camera iris.

Video Monitors

  • Dual 17 in high resolution, anti-glare, anti-static.
  • Ambient room light sensor.
  • Multi-LED X-ray “ON” indicator.

Hardcopy Options

  • Thermal printer. (optional)
  • DICOM. (optional)
  • Image Capture Device. (optional)
  • Laser aiming device. (optional)

C-Arm Dimensions

  • Height: 71 / 91 in. (1805 / 2305 mm)
  • Width: 35 in. (880 mm)
  • Length: 76 in. (1930 mm)
  • Weight: 695 lbs 315 kg.

Workstation Dimensions

  • Height: 69 in (1760 mm)
  • Width: 32 in (800 mm)
  • Depth: 37 in (925 mm)

 