Philips M4841A IntelliVue Features
The Philips M4841A IntelliVue Telemetry Transmitter is a lightweight, portable telemetry transmitter with integrated ECG & SPO2 monitoring capability. Each transceiver model provides bi-directional communication with the Philips IntelliVue Information Center.
- Compact, lightweight transceivers
- Clinical operator-initiated Audible Page/Find Device alerts for locating the device (initiated from the IntelliVue Information Center)
- Patient/clinical operator-initiated Multifunction Telemetry Button (configurable) allows for Nurse 0Call, Remote Recordings, both or neither. Also controls Alarm Pause/Suspend when pressed along with the Check Button
- 3-Minute Alarms Pause/ Suspend and Indicator – clinical operator initiated at transceivers or central station. Resume monitoring from Standby
- Out-of-Range audible alert
- Check the button to confirm the battery status, Lead- set in use (3, 5, or 6), and EASI mode
- Vivid electrode placement diagrams (AAMI or IEC) on the transceiver case (EASI, Standard, MCL, and V-Leads)
Philips M4841A IntelliVue Telemetry Transmitter Specifications
Dimensions
- Height: 5.6 in (140 mm)
- Width: 3.52 in (88 mm)
- Width: 1.48 in (37 mm)
- Weight: (ECG + Spo2):
- <324 g ( 11.5 oz) with 5-Wire Leadset and 2 AA batteries
- <255 g ( 9.0 oz0 with 2 AA eateries
- 204 g (7.2 oz) without 2 AA Battereis
- Weight: (ECG Only)
- 284 g (10 oz. ) with 3-wire Leadset and 2 AABattereis
- 210 g (7.4 oz.) with 2 AA Batteries
- 162 g (5.7 oz.) without 2 AA Batteries
- Volume: 300 cm
Environmental Characteristics
- Operating Temperature: 0°C to +37° C (32°F to 99°F)
- NOTE: Sp)2 sensors have a maximum operating temperature of 37°C (99°F).
- Operating Humidity: <95% RH @ 40o C (104o F) non-condensing
- Storage Temperature (without batteries): -40o C to +60o C (-40o F to +140o F)
- Storage Humidity: <90% RH non-condensing @ 60o C (140o F)
- Altitude: Operating and storage up to 3048 meters (10,000 feet)
- Shock Resistance: Withstands 1.2 meter (4 foot) drop to vinyl-covered concrete surface with only cosmetic damage.
- Water Resistance: Withstands 5- minute submersion in 30.5 cm (1 foot) of water, Withstands 10-minute water exposure in a shower when used in conjunction with a closed pouch.
- Cross-infection Prevention: The transmitter can be sterilized with Ethylene Oxide (EO) to cross infection assurance level 10E-6.
Electrical
- Batteries: Uses two 1.5V AA Alkaline Batteries (tested with DURACELL MN1500 batteries – see Battery Life Expectancy specifications)