Drager Carina

Quotes in less than 24 hours Download Specifications

Drager Carina Ventilator Features

The Drager Carina is a NIV Ventilator. This means that instead of invasively delivering ventilation through the patient’s windpipe, it is delivered through the mouth or even the nose through a mask that goes over the patient’s face. Making it more comfortable for the patient and caregiver. The Carina features a wide range of ventilation modes from spontaneous and mandatory to some that can integrate blenders and supply a combination of oxygen and gases.

The Carina System includes SyncPlus Technology that can compensate for a variety of leakage rates. Meaning the patient can breathe easier with the machine without exerting themself and using unnecessary energy. The Compact design helps to ensure reliable ventilation therapy during transport or even bedside. The Carina Ventilator has a TFT color display that can showcase a variety of values and information as well as being customizable for particular needs.

  • Lightweight design that is ideal for mobilization and intra-hospital transport
  • Offering Spontaneous and mandatory ventilation for non-invasive and invasive therapies
  • For Sub-acute care patients
  • Only meant for Adult Patients

Drager Carina Specifications

Dimensions

Basic Device:

  • Width: 6.9 in ( 175mm)
  • Height:10.8in (275mm)
  • Depth: 15.2in (385mm)

Trolley:

  • Width: 34.7 cm (880mm)
  • Height: 22.4 cm (570mm)
  • Depth: 67.06 cm (670mm)

Weight

  • 5.5 kg (12.1 lb) (basic device)
  • 14.8 kg (32.6 lb) (trolley)

Screen

  • TFT color screen 13.7 cm (5.4 in)

Performance Data

  • Control principle: Time or Flow-controlled and pressure or volume-controlled
  • Disconnection detection: automatic
  • Reconnection detection: automatic (also on standby)
  • Grid voltage: Grid voltage 100 V to 240 V AC, 50/60 Hz
  • power input: At 100 VAC max 1.1 A, AT 240 VAC Max 0.5 A
  • Maximum Power Consumption: 90 W (in operation, when loading the internal battery)
  • Typical Power Consumption:35 W (in operation, when loading the internal battery)
  • Operating period of internal battery: 60 min.
  • Noise level: 40 dB (A) )with typical ventilation)

Gas supply HPO

  • O2 positive operating pressure:
  • 2.7 bar to 6 bar
  • 270 kPa to 600 kPa
  • 40 psi to 87 psi

Gas supply LPO

  • O2 positive operating pressure
  • 0 to 500 mbar (or hPa or cmH2O)
  • O2-Flow 0 to 10 L/min
  • Supply system for patient flow Turbine
  • Maximum continuous inspiratory flow: 180 L/min, BTPS (max. 120 L/min with 100 % O2)

Refurbished of The Drager Carina Ventilator

Soma Tech Intl offers the Drager Carina Ventilator machine up to 50% below OEM prices with the same service and warranty as new. The Drager Carina is not only technically refurbished but also cosmetically refurbished to make it work and look like new. When the refurbishing process starts on the ventilator, it is carefully inspected and tested by our own in-house biomedical engineers that are highly skilled and certified to work on Ventilators. If necessary, parts are replaced to make sure that all aspects of the Drager ventilator machine to the original engineering manufacturer specifications. This ensures that the unit is working the same way that it originally left the manufacturer. After the Carina Ventilator is working like new it undergoes a special cosmetic restoration process. The Drager is cleaned, minor scratches and dents are repaired, it’s painted, and new decals are replaced if necessary. After this strenuous refurbishing process, the unit functions and looks like new. Soma Tech Intl is ISO 13485 certified and ensures that the best quality is given to all capital medical equipment that they sell. Before the Drager Ventilator is labeled patient-ready and packed up for shipment, it goes through one last quality control test that makes sure all aspects are again working as they should. If you are looking to buy refurbished surgical tables contact soma at [email protected] or call us at 1-800-GET-SOMA.

Soma Tech Intl is actively looking to purchase Drager Carina ventilators, If you or your facility is looking to sell your ventilator system, be sure to contact Soma Tech Intl. Soma has a dedicated and experienced purchasing department that helps you through the entire process. Selling your used or pre-owned Drager ventilator takes out the middle man in the equation. This also ensures that your medical facility gets top dollar for your equipment. Soma is 100% HIPPA compliant and makes sure that your equipment gets to our facility in the same condition that it left yours. Soma Tech Intl also gives the option for trade-in credit on your medical equipment. If you or your facility is looking to regain space for new equipment, or if you are looking to upgrade your current equipment, contact Soma Techn Intl’s purchasing department at [email protected] or send us a message on our Sell to Soma website.

Banner

Questions about our ventilators?

Soma Tech Intl offers a wide range of ventilators. If you have any questions about any of our ventilators or need a quick quote, call us and one of our knowledgeable sales representatives will help you.

Looking to sell your ventilators? Soma ensures your facility gets top dollar for your equipment and also gives the option for trade-in credit.

1-800-GET-SOMA
Contact Us