LivaNova Sorin Stockert 3T
24-Hour QuotesPricing up to 50% below the cost of new,
with service and warranty included. Download Specifications
Sorin Stockert 3T Features
The LivaNova Sorin Stockert 3T is a heater-cooler that is used during cardiopulmonary bypass. The System is used to help regulate the patient’s blood during cardiac, vascular, and transplant procedures. The Stockert 3T system can work independently from the water supply in an operating room. It comes with three different water tanks that control the warming and cooling cardioplegias along with the patient’s temperature. Each one of these is on its own separate circuit and can be run simultaneously. The Sorin Stockert heating and cooling of the system runs off of one circuit while the patient temperature runs off of two circuits. The water in the LivaNova 3T does not come in contact with the patient’s or the patient’s blood during a procedure.
At the end of a procedure, the water can be drained out of the heat exchange, and the tubing to help with clean up.
- Short pre-cooling time
- 2 Small volume tanks for warming and Cooling
- Independent safety system to prevent the water temperature from reaching critical temperatures
- Two-chamber pumps to minimize the pressure inside the heating chamber
- The Suction of the pumps allows for a smooth emptying of the heating chamber and the tubing
3T Heart-Cooler Specifications
Dimensions
- Height: 33.2 in (97.5 cm)
- Width: 19.8 in (50 cm)
- Depth: 26.8 in (68 cm)
- Weight: 228.5 lbs (102 kg)
Operating Conditions
- Operating Temperature: 10 °C through 30 °C Note: Cooling performance might be reduced at operating temperatures greater than 25 °C.<?li>
- Relative Humidity: 30% through 75%
- Operating altitude (atmospheric pressure): 0 … 2,000 m (700hPa … 1,060 hPa)
Storage Conditions
- Storage Temperature: -10 °C through 60 °C
- Relative Humidity: 0% through 80%
- Atmospheric Pressure: 500 hPa through 1,060 hPa (7.3 psi through 15.4 psi)
Transport Conditions
- Transport Temperature: -10 °C through 60 °C
- Relative Humidity: 0% through 85%
- Atmospheric Pressure: 500 hPa through 1,060 hPa (7.3 psi through 15.4 psi)
Volume and Flow
- Minimum level patient tank 4.5 L (11.6 L total tank volume)
- Maximum level patient tank 6.5 L (13.8 L total tank volume)
- Water flow patient circuits
- 13.0 – 16.4 liters per minute (circuit outlet)
- 10.8 – 12.6 liters per minute (5 m + 5 m circuit)
- Water flow cardioplegia circuit
- 7.5 – 9.8 liters per minute (circuit outlet)
- 7.4 – 8.7 liters per minute (5 m + 5 m circuit)
- Water pressure in patient circuits 0.63 – 0.79 bar
- Water pressure in cardioplegia circuits 0.65 – 0.72 bar
Power
- Power Needed, VAC: 110/220-240
Connectors
- Number: 6 (3 circuits)
Alarms
- High-temperature fluid limit: Visual, audible
- Low fluid: Visual, audible
General
- LIQUID USED: Tap water; sterile water
- Flow L/hr: 15-17 L/min for patient, 9-11 L/min for cardioplegia
- Flow indicator: Yes
- Temperature Scale Readout: Celsius
- Reservoir Number: 3
- Reservoir Capacity, l: 6 (1.6), 3 (0.8), 3 (0.8)
- Alarm Silence: Yes
Refurbished LivaNova Sorin Stockert 3T Heater/Cooler Systems
Soma Tech Intl offers Refurbished LivaNova Sorin Stockert 3T heater/cooler systems up to 50% below OEM prices with the same service and warranty as new. The Sorin 3T heater/cooler unit is not only technically refurbished but also cosmetically refurbished to make it work and look like new. When the refurbishing process starts on the LivaNova heater/cooler system it’s carefully inspected and tested by our own in-house biomedical engineers that are highly skilled and certified to work on 3T heater/coolers. If necessary, parts are replaced to make sure that all aspects of the heater/cooler are functioning properly. Once everything is in working order, the unit is calibrated back to the original engineering manufacturer’s specifications. This ensures that the unit is working the same way that it originally left the manufacturer. After the LivaNova 3T heater/cooler machine is working like new it undergoes a special cosmetic restoration process. The Stockert 3T is cleaned, minor scratches and dents are repaired, it’s painted, and new decals are replaced if necessary. After this strenuous refurbishing process, the unit functions and looks like new. Soma Tech is ISO 13485 certified and ensures that the best quality is given to all capital medical equipment that they sell. Before the LivaNova 3T heater/cooler unit is labeled patient-ready and packed up for shipment, it goes through one last quality control test that makes sure all aspects are again working as they should. If you are looking to buy a refurbished LivaNova Sorin Stockert 3T contact soma at [email protected] or call us at 1-800-GET-SOMA.
Soma Tech Intl is also actively looking to purchase a LivaNova Sorin Stockert 3T heater/cooler system. If you or your facility is looking to sell your Sorin 3T, be sure to contact Soma Tech Intl. Soma has a dedicated and experienced purchasing department that helps you through the entire process. Selling your used or pre-owned Sorin Stockert 3T heater/cooler systems to Soma Tech takes out the middle man in the equation. This also ensures that your medical facility gets top dollar for your equipment. Soma Tech is 100% HIPPA compliant and makes sure that your equipment gets to our facility in the same condition that it left yours. Soma Tech also gives the option for trade-in credit on your medical equipment. If you have medical equipment you would like to sell to Soma, send us a message here!