Drager Infinity M300
24-Hour QuotesPricing up to 50% below the cost of new,
with service and warranty included. Download Specifications
Drager Infinity M300 Features
The Drager Infinity M300 is a hand-held pulse oximeter and patient monitor that has the ability to monitor ECG, Heart rate, SpO2. The M300 system uses wireless network technology and a monitoring station to continuously monitor the patient even when out of range. The Drager M300 can be used on patients from pediatrics to adults. With a color display and a built-in alarm system, you can easily see and respond to the patient’s needs.
- Built-in color screen with waveforms and vital sign values, providing local surveillance to augment monitoring at the Infinity Central Station.
- Visible and audible alarms that immediately alert you to changes in the patient’s condition.
- Integrated Arrhythmia Classification Expert (ACE®) and pacer detection algorithms.
- Built-in SpO2, eliminating the need for an additional pulse oximetry device or module.
- Wi-Fi CERTIFIED technology for reliable data transfer on standard wireless networks.
- Support for WPA2 encryption using 802.11 b/g.
Drager Infinity M300 Specifications
Dimensions
- Height: 5.6 In (14.2 cm)
- Width: 3 In (7.6 cm)
- Depth: 1.2 In (3.1 cm)
- Weight: 10.5 oz (295 g)
Display
- Size / Viewing Area: 2.2 In (5.5 cm) diagonal
- Resolution: 220 x 176 pixels
Communications
- Network: IEEE 802.11b/g/n (2.4 GHz); 802.11a/n (5 GHz)
- Wireless Encryption: WPA2 – Personal Mode; WPA2 – Enterprise Mode
- Radio Power Output: (2.4 GHz); 25mW maximum (5 GHz)
Battery
- Power Source: Rechargeable 3.75 V lithium-ion battery
- Battery Operating Time:
- ECG only: 17 to 19 hours
- ECG + Continuous SpO2: 14 to 16 hours
- Operation time varies according to the use of display, alarm alerts, and wireless environment (roaming)
ECG
- Adult / Pediatric
- 5-wire: I, II, III, aVR, aVL, aVF, V
- 6-wire: I, II, III, aVR, aVL, aVF, V, V+
- 6-wire with Infinity TruST 12-lead: I, II, III, aVR, aVL, aVF, dV1, V2, dV3, dV4, V5, dV6
- Detected Events / Rhythms: Asystole, Ventricular Fibrillation, Ventricular Tachycardia, Bradycardia, Ventricular Run, Accelerated Idioventricular Rhythm, Supraventricular Tachycardia, Ventricular Couplet, Ventricular Bigeminy, Tachycardia, Pause, Artifact, PVC/min
Pacemaker
- Detection Leads: I and (II or III)
- Detection Amplitude: ±2 to ±700 mV
- Detection Width: 0.1 to 2.0 ms
ST Segment Analysis
- Leads Analyzed:
- 3-wire: I, II, or III
- 5-wire: I, II, III, aVR, aVL, aVF, V
- 6-wire: I, II, III, aVR, aVL, aVF, V, V+
- 6-wire with Infinity TruST 12-lead: I, II, III, aVR, aVL, aVF, dV1, V2, dV2, dV3, dV4, V5, dV6
Pulse Oximetry (Optional)
- Parameter Display: Percentage of functional (oxygen-saturated) hemoglobin (%SpO2); pulse rate
- Measuring Method: Absorption-spectrophotometry